2020
DOI: 10.1016/j.jcin.2020.06.053
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter Edge-to-Edge Mitral Valve Repair With the MitraClip G4 System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
64
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 77 publications
(81 citation statements)
references
References 11 publications
1
64
0
Order By: Relevance
“…The fibrous encapsulation of the clip over time might stabilize the leaflet insertion, so late SLDA is a rare finding. There has been a continuous reduction in SLDA over years, which likely reflects the implanter's learning curve and advances in the clip systems: EVEREST I 11.0%, EVEREST II 5.1%, ACCESS-EU 4.8%, TRAMI 2.0%, TVT 1.5%, Praz et al 4.0%, Mitra EXPAND 1.9%, and "G4" 1.7% [5,13,14,16…”
Section: Structural Device Failurementioning
confidence: 99%
“…The fibrous encapsulation of the clip over time might stabilize the leaflet insertion, so late SLDA is a rare finding. There has been a continuous reduction in SLDA over years, which likely reflects the implanter's learning curve and advances in the clip systems: EVEREST I 11.0%, EVEREST II 5.1%, ACCESS-EU 4.8%, TRAMI 2.0%, TVT 1.5%, Praz et al 4.0%, Mitra EXPAND 1.9%, and "G4" 1.7% [5,13,14,16…”
Section: Structural Device Failurementioning
confidence: 99%
“…The MitraClip currently has a fourth-generation ‘G4’ device, which has been enhanced with an expanded range of four clip sizes (NTR, NTW, XTR, XTW), differentiated by clip arm length and width, independent leaflet grasping feature and real-time left atrial (LA) pressure monitoring capabilities. [ 19 , 20 ] The G4 system is already available in parts of Asia and these new features could aid in the treatment of challenging anatomies.…”
Section: Mitraclip Use In Functional Mitral Regurgitationmentioning
confidence: 99%
“…Recent device iterations (i.e., MitraClip G4) feature separate grasping ability and different arm/gripper width, and facilitate real-time LA-pressure monitoring on the guide catheter. Initial results of a study including 59 patients showed residual MR (grade › 2+) in 3.5%, which appears to be surpassing the results of large trials in terms of MR grade reduction [ 30 ]. In particular for SMR, wider arms might contribute to enhanced leaflet apposition as none of the patients in the SMR arm had SMR grade › 2 at 30 days follow-up.…”
Section: Edge-to-edge Leaflet Coaptationmentioning