1997
DOI: 10.1007/s002469900193
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter Closure of Atrial Septal Defects by the “Buttoned” Device: Complications and Need for Surgical Revision

Abstract: Immediate and medium-term experience with transcatheter closure of a secundum atrial septal defect by the "buttoned" device in seven patients is reported. Complications occurred in two patients during the procedure. In one patient with complications, the occluder was partly released in the right atrium. All efforts to correct its position were unsuccessful and caused considerable deformation of the device, which had to be removed surgically. In the other patient with complications, disconnection of the occlude… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0
1

Year Published

1999
1999
2009
2009

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 12 publications
0
10
0
1
Order By: Relevance
“…Interference with mitral valve function and even structural damage to the mitral valve has been reported with atrial septal occluder devices [4–6]. To our knowledge, the case detailed in this report is the only case of HELEX device fracture resulting in perforation of a valve leaflet.…”
Section: Discussionmentioning
confidence: 85%
“…Interference with mitral valve function and even structural damage to the mitral valve has been reported with atrial septal occluder devices [4–6]. To our knowledge, the case detailed in this report is the only case of HELEX device fracture resulting in perforation of a valve leaflet.…”
Section: Discussionmentioning
confidence: 85%
“…One of the major concerns for the buttoned device is the correct positioning of the occluder through the defect. 12 Indeed, several obturators were used in 24 of the 73 patients before we could achieve adequate placement. This gives a ratio of 1.3 occluder per patient for both groups.…”
Section: Discussionmentioning
confidence: 99%
“…The complication rate seems to be quite low, comparable to surgical results [7, 8]. Nevertheless, embolic events, arrhythmias, infection, thrombus formation, transient ischemic attack, and transient repolarization disorders may occur [5, 6, 9–12], requiring surgical management [13, 14]. Perforation of the left atrium resulting in a fistula from the left atrium to the aortic sinus is described in this case report.…”
Section: Introductionmentioning