2022
DOI: 10.1126/sciadv.add3854
|View full text |Cite
|
Sign up to set email alerts
|

Tracking the vector acceleration with a hybrid quantum accelerometer triad

Abstract: Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold atom–based quantum inertial sensors can potentially provide these high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 62 publications
(89 reference statements)
0
9
0
Order By: Relevance
“…In order to properly compare the long-term stability of the angular velocity measurement made by an AAA, we model the statistical properties of the atomic accelerometers from Ref. 20 . Namely a single-shot measurement resolution of 7.6×10 −5 ms −2 , and a bias drift of 5.9 × 10 −7 ms −2 /day.…”
Section: Long-term Stability Of ω ω ωmentioning
confidence: 99%
See 4 more Smart Citations
“…In order to properly compare the long-term stability of the angular velocity measurement made by an AAA, we model the statistical properties of the atomic accelerometers from Ref. 20 . Namely a single-shot measurement resolution of 7.6×10 −5 ms −2 , and a bias drift of 5.9 × 10 −7 ms −2 /day.…”
Section: Long-term Stability Of ω ω ωmentioning
confidence: 99%
“…Even for very large arrays with l = 2.0 m, the attainable single-shot resolution of ∼ 10 −5 rad•s −1 is greatly outperformed by state of the atomic gyroscopes, whose single-shot resolution is on the order of ∼ 10 −8 − 10 −9 rad•s −135 . The single-shot resolution of the AAA can be improved upon by introducing additional accelerometers, however, the most practical way of rivaling atomic accelerometers is by hybridizing the array of accelerometers with classical sensors 15,20 ; note that this does not defeat the purpose of an AAA, as their most impactful contribution is long-term stability.…”
Section: Size Limitationsmentioning
confidence: 99%
See 3 more Smart Citations