1979
DOI: 10.13182/nt79-a32183
|View full text |Cite
|
Sign up to set email alerts
|

Tracer Techniques for the Input Accountability of Plutonium in Reprocessing Plants: Magtrap and Leadtrap

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1980
1980
2016
2016

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…A novel approach using a suitable tracer was developed and tried by several researchers. [82][83][84][85][86][87][88][89][90][91][92][93][94][95][96][97][98][99][100] This involves the addition of a known amount of tracer element to the input accountability tank, suitable homogenisation and mixing of the tracer with the solution in the tank and taking any unknown aliquot from the solution. By determining tracer to Pu and tracer to U amount ratios by ID-TIMS, and knowing accurately the amount of tracer added, the total amount of Pu and U in the tank can be determined.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
confidence: 99%
See 1 more Smart Citation
“…A novel approach using a suitable tracer was developed and tried by several researchers. [82][83][84][85][86][87][88][89][90][91][92][93][94][95][96][97][98][99][100] This involves the addition of a known amount of tracer element to the input accountability tank, suitable homogenisation and mixing of the tracer with the solution in the tank and taking any unknown aliquot from the solution. By determining tracer to Pu and tracer to U amount ratios by ID-TIMS, and knowing accurately the amount of tracer added, the total amount of Pu and U in the tank can be determined.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
confidence: 99%
“…in the MAGTRAP (Magnesium Tracer for input Accountability of Pu) and LEADTRAP (Lead Tracer for input Accountability of Plutonium), during studies carried out by us at Tarapur. 84,85 Subsequently, the European Community tried different tracers (Nd, Lu and Pb) in RITCEX (Reprocessing Input Tank Calibration Exercise) at Eurochemie Reprocessing Plant with different tracers yielding similar results. [89][90][91]95 Another exercise CALDEX (Calibration Demonstration Exercise) was also taken up in the framework of European collaboration and evaluation of the tracers methodology.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
confidence: 99%