“…A novel approach using a suitable tracer was developed and tried by several researchers. [82][83][84][85][86][87][88][89][90][91][92][93][94][95][96][97][98][99][100] This involves the addition of a known amount of tracer element to the input accountability tank, suitable homogenisation and mixing of the tracer with the solution in the tank and taking any unknown aliquot from the solution. By determining tracer to Pu and tracer to U amount ratios by ID-TIMS, and knowing accurately the amount of tracer added, the total amount of Pu and U in the tank can be determined.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
confidence: 99%
“…in the MAGTRAP (Magnesium Tracer for input Accountability of Pu) and LEADTRAP (Lead Tracer for input Accountability of Plutonium), during studies carried out by us at Tarapur. 84,85 Subsequently, the European Community tried different tracers (Nd, Lu and Pb) in RITCEX (Reprocessing Input Tank Calibration Exercise) at Eurochemie Reprocessing Plant with different tracers yielding similar results. [89][90][91]95 Another exercise CALDEX (Calibration Demonstration Exercise) was also taken up in the framework of European collaboration and evaluation of the tracers methodology.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
The advances which have taken place during the last four decades in the instrumentation and applications of thermal ionisation mass spectrometry (TIMS) particularly of relevance to nuclear science and technology are highlighted.
“…A novel approach using a suitable tracer was developed and tried by several researchers. [82][83][84][85][86][87][88][89][90][91][92][93][94][95][96][97][98][99][100] This involves the addition of a known amount of tracer element to the input accountability tank, suitable homogenisation and mixing of the tracer with the solution in the tank and taking any unknown aliquot from the solution. By determining tracer to Pu and tracer to U amount ratios by ID-TIMS, and knowing accurately the amount of tracer added, the total amount of Pu and U in the tank can be determined.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
confidence: 99%
“…in the MAGTRAP (Magnesium Tracer for input Accountability of Pu) and LEADTRAP (Lead Tracer for input Accountability of Plutonium), during studies carried out by us at Tarapur. 84,85 Subsequently, the European Community tried different tracers (Nd, Lu and Pb) in RITCEX (Reprocessing Input Tank Calibration Exercise) at Eurochemie Reprocessing Plant with different tracers yielding similar results. [89][90][91]95 Another exercise CALDEX (Calibration Demonstration Exercise) was also taken up in the framework of European collaboration and evaluation of the tracers methodology.…”
Section: Accountability Of Pu and U At Reprocessing Plantsmentioning
The advances which have taken place during the last four decades in the instrumentation and applications of thermal ionisation mass spectrometry (TIMS) particularly of relevance to nuclear science and technology are highlighted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.