2020
DOI: 10.1016/j.apr.2019.12.012
|View full text |Cite
|
Sign up to set email alerts
|

Traceability of the output concentration of mercury vapor generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…The mass of collected Hg is subsequently analyzed using ID-CV-ICP-MS. Below, we describe key features of the overall sampling method, noting that the underlying principles and methodologies of Hg 0 generator, sorbent trap, ID-CV-ICP-MS, and LAS have been published earlier. [12][13][14]17 The notations Hg and MS represent the Hg 0 state and ID-CV-ICP-MS, respectively, when not explicitly indicated.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The mass of collected Hg is subsequently analyzed using ID-CV-ICP-MS. Below, we describe key features of the overall sampling method, noting that the underlying principles and methodologies of Hg 0 generator, sorbent trap, ID-CV-ICP-MS, and LAS have been published earlier. [12][13][14]17 The notations Hg and MS represent the Hg 0 state and ID-CV-ICP-MS, respectively, when not explicitly indicated.…”
Section: Methodsmentioning
confidence: 99%
“…The volumetric flow rate of the gas passing through the sorbent tube is measured using a calibrated laminar flow element (LFE) flowmeter, and this quantity is integrated over the collection time to provide the total volume of carrier gas associated with the mercury that is collected by the trap. The mass of collected Hg is subsequently analyzed using ID-CV-ICP-MS. Below, we describe key features of the overall sampling method, noting that the underlying principles and methodologies of Hg 0 generator, sorbent trap, ID-CV-ICP-MS, and LAS have been published earlier. , The notations Hg and MS represent the Hg 0 state and ID-CV-ICP-MS, respectively, when not explicitly indicated.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…NIST SRM 3133 (Mercury Standard Solution) was used for calibrating the ICP-MS method. Since NIST SRM 3133 is traceable to SI units, an unbroken chain of traceability to SI units was achieved [ 15 ]. Srivastava et al [ 16 ] applied a high-resolution absorption spectroscopy method to achieve SI traceability for the GEM measurement.…”
Section: Introductionmentioning
confidence: 99%