2015
DOI: 10.1007/s10765-015-1915-2
|View full text |Cite
|
Sign up to set email alerts
|

Traceability of a CCD-Camera System for High-Temperature Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…The traceable calibration of an Imaging Luminance Measurement Device (ILMD) or of the luminance distribution of a light source requires knowledge about numerous contributions to measurement errors and uncertainties. Typically, a light source with a uniform luminance is used to characterize the relative non-uniformity of the photo-response (PRNU) (Bünger et al, 2015). In case of a non-uniform luminance, a sequence of translation can be used (Ferrero et al, 2014).…”
Section: Motivation Specific Objectivementioning
confidence: 99%
“…The traceable calibration of an Imaging Luminance Measurement Device (ILMD) or of the luminance distribution of a light source requires knowledge about numerous contributions to measurement errors and uncertainties. Typically, a light source with a uniform luminance is used to characterize the relative non-uniformity of the photo-response (PRNU) (Bünger et al, 2015). In case of a non-uniform luminance, a sequence of translation can be used (Ferrero et al, 2014).…”
Section: Motivation Specific Objectivementioning
confidence: 99%
“…An electric signal is generated and a Digital Level (DL) is obtained for the corresponding pixel, ultimately forming an image. Several post-processing techniques may then be applied to improve the accuracy of the raw signal, for instance bad pixel replacement functions [42]. Software-based nonuniformity correction (NUC) corrected the non-uniform distribution of radiation being absorbed across the sensor due to the camera optics, which is discussed in Section 3.3.…”
Section: Camera Calibrationmentioning
confidence: 99%
“…BP neural network training samples are used to obtain the quality and safety evaluation results [11]. A forewarning system of aquatic product safety is put forward in the literature [12]. Based on the comprehensive study of food safety early-warning theory and intelligence theory, a food safety intelligent early warning system is put forward [13].…”
Section: Literature Reviewmentioning
confidence: 99%