2005
DOI: 10.1016/j.nimb.2005.06.182
|View full text |Cite
|
Sign up to set email alerts
|

Trace element fingerprinting of façon-de-Venise glass

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
21
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(23 citation statements)
references
References 6 publications
2
21
0
Order By: Relevance
“…Glass produced in central Europe and Venice between 11th to 14th centuries frequently reflects soda ash glass composition [4][5][6]. Typical soda ash glass contains sodium and calcium oxides in a weight proportion of almost 1.4:1 and relatively high amount of magnesium and potassium oxides due to use of quartz and the ash of halophytic plants for production [4][5][6][7]. Soda lime glass was produced from 900 BC to the Middle Ages from quartz, trona and lime.…”
Section: Introductionmentioning
confidence: 99%
“…Glass produced in central Europe and Venice between 11th to 14th centuries frequently reflects soda ash glass composition [4][5][6]. Typical soda ash glass contains sodium and calcium oxides in a weight proportion of almost 1.4:1 and relatively high amount of magnesium and potassium oxides due to use of quartz and the ash of halophytic plants for production [4][5][6][7]. Soda lime glass was produced from 900 BC to the Middle Ages from quartz, trona and lime.…”
Section: Introductionmentioning
confidence: 99%
“…The results of sensitive LA-ICP-MS elemental/isotopic measurements can be used to support the use of other instrumental meth- ods such as Scanning Electron Microscopy with Energy Dispersive X-Ray Spectrometry (SEM-EDS) [12,31,38,74,79,112,118,130,135,166,170,181,182], Electron Probe Microanalysis (EPMA) [75, 80, 81, 97, 112, 167, 183 -185], X-Ray Fluorescence (XRF) [16,31,35,44,93,94,98,119,120], Proton Induced X-Ray Emission [22,41,95,114,186,187] or Neutron Activation Analysis (NAA) [23, 36, 99, 100, 107, 108, 114, 146, 188 -192]. Leroy et al [193] reported the first application of confocal Synchrotron Radiation micro X-Ray Fluorescence (SR-m-XRF) with LA-ICP-MS.…”
Section: Multi-technique Approach Incorporating La-icp-msmentioning
confidence: 99%
“…Sample preparation is usually accomplished by embedding small glass fragments in an acrylic resin and subsequently polishing the surface [64][65][66][67], while larger, centimetric fragments were directly analyzed byŠmit et al [68]. Resin enclosure and polishing enable the analysis of cross sections and the removal of up to millimetric thick contaminated and/or depleted surface layers.…”
Section: Glass Artifactsmentioning
confidence: 99%
“…[65]). Alternatively, when only a thin layer has to be removed, a pre-ablation scan may be used for exposing a 'clean' surface [68].…”
Section: Glass Artifactsmentioning
confidence: 99%
See 1 more Smart Citation