2006
DOI: 10.1016/j.gca.2006.06.1383
|View full text |Cite
|
Sign up to set email alerts
|

Trace element and isotopic composition of GJ-red zircon standard by laser ablation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

58
112
13
12

Year Published

2011
2011
2017
2017

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 653 publications
(202 citation statements)
references
References 2 publications
58
112
13
12
Order By: Relevance
“…Zircon GJ1 was used as the reference standard, with a weighted mean 176 Hf/ 177 Hf ratio of 0.282007 ± 0.00008 (2r, n = 19) during our routine analyses. It is in agreement with the recommended weighted mean 176 Hf/ 177 Hf ratio of 0.282013 ± 19 (2r) of the GJ1 (Elhlou et al, 2006). The measured 176 Lu/ 177 Hf ratios and the 176 Lu decay constant of 1.867 Â 10 À11 yr À1 reported by Soderlund et al (2004) Bouvier et al (2008) were used for the calculation of e Hf (t) values.…”
Section: Lu-hf Isotope Analysissupporting
confidence: 84%
“…Zircon GJ1 was used as the reference standard, with a weighted mean 176 Hf/ 177 Hf ratio of 0.282007 ± 0.00008 (2r, n = 19) during our routine analyses. It is in agreement with the recommended weighted mean 176 Hf/ 177 Hf ratio of 0.282013 ± 19 (2r) of the GJ1 (Elhlou et al, 2006). The measured 176 Lu/ 177 Hf ratios and the 176 Lu decay constant of 1.867 Â 10 À11 yr À1 reported by Soderlund et al (2004) Bouvier et al (2008) were used for the calculation of e Hf (t) values.…”
Section: Lu-hf Isotope Analysissupporting
confidence: 84%
“…Zircon 91500 was used as the reference standard for calibration and controlling the condition of analytical instrumentation (Woodhead et al, 2004). The obtained 176 Hf/ 177 Hf ratio was 0.282296 ± 0.000050 (2r) for 91500 and 0.282019 ± 15 (2r) for GJ-1, which is in good agreement with the recommended 176 Hf/ 177 Hf ratios of 0.2823075 ± 0.0000058 (2r) for 91500 and 0.282015 ± 0.000019 (2r) for GJ-1 (Elhlou et al, 2006;Wu et al, 2006).…”
Section: Zircon Lu-hf Isotopessupporting
confidence: 83%
“…Helium was used as a carrier gas to provide efficient aerosol delivered to the torch. The instrumental conditions and data acquisition have been comprehensively described by Hou et al [32] Zircon GJ1 was used as the reference standard during our routine analyses, with a weighted mean 176 Hf/ 177 Hf ratio of 0.281996 ± 1 (2SD, n = 12), which is in good agreement with the previously reported data within errors [35,36]. We chose two-stage Hf model age (T Hf2 ) for tracing material source [37].…”
Section: Analytical Proceduresmentioning
confidence: 67%