2011
DOI: 10.1016/j.chroma.2011.01.014
|View full text |Cite
|
Sign up to set email alerts
|

Trace analysis of 28 steroids in surface water, wastewater and sludge samples by rapid resolution liquid chromatography–electrospray ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
195
1
1

Year Published

2012
2012
2016
2016

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 286 publications
(206 citation statements)
references
References 31 publications
9
195
1
1
Order By: Relevance
“…These limits are 0.035 ng/L for EE2 and 0.4 ng/L for E2 (European Parliament 2015). These contaminants in an average equipped laboratory using multiresidue analysis without derivatization can only be determined with poor LOQ values (Liu et al 2011b, Loos et al 2010, Ripolles et al 2014). Our methodology with dansyl derivatization is cheap, quick and simple enough to be considered for use in monitoring studies in the future.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These limits are 0.035 ng/L for EE2 and 0.4 ng/L for E2 (European Parliament 2015). These contaminants in an average equipped laboratory using multiresidue analysis without derivatization can only be determined with poor LOQ values (Liu et al 2011b, Loos et al 2010, Ripolles et al 2014). Our methodology with dansyl derivatization is cheap, quick and simple enough to be considered for use in monitoring studies in the future.…”
Section: Discussionmentioning
confidence: 99%
“…Full MS and targeted MS/MS methods without derivatization, which are generally used in environmental monitoring applications, detect 40-100 or even more target compounds. These screening methods however often do not include or cannot detect E2 and EE2 due to poor detection limits (Chitescu et al 2015, Kuster et al 2008, Liu et al 2011b, Loos et al 2010. Evaluation of derivatives of estrogens makes positive mode electrospray ionization (ESI) mass spectrometric detection possible and improves generally the sensitivity of MS methods (Anari et al 2002, Xu &Spink 2008.…”
Section: Introductionmentioning
confidence: 99%
“…The extraction and instrumental analysis followed the authors' previous methods. [22][23][24][25] In brief, the collected water samples (1 L each) from the STP and the laboratory experiment were ltered through prebaked glass ber lters (GF/F, Whatman 0.45 mm pore-size) before extraction. Then 50 mL methanol and 200 mL 4 M H 2 SO 4 were added immediately to each 1 L bottle to adjust the pH to 3.0.…”
Section: Analysis Of Organic Compoundsmentioning
confidence: 99%
“…Extraction of water samples and chemical analysis were performed according to Liu et al (2011). For measurement of P or T, the water samples were filtered through a 0.45 μm membrane filter and directly analyzed by RRLC-MS/MS.…”
Section: Measurement Of Hormone Concentrations In Watermentioning
confidence: 99%