2016 IEEE International Conference on Dielectrics (ICD) 2016
DOI: 10.1109/icd.2016.7547585
|View full text |Cite
|
Sign up to set email alerts
|

Towards space charge measurements by (F)LIMM under DC electric field

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Besides, to perform measurements on thin sample it is possible to work with a PEA cell offering a better resolution [18]. Finally in order to study the space charge distribution in thin sample we may also use the Laser Intensity Modulated Method -LIMM that has already been recently developed to work under applied voltage conditions [19].…”
Section: Space Charge Distribution Profilesmentioning
confidence: 99%
“…Besides, to perform measurements on thin sample it is possible to work with a PEA cell offering a better resolution [18]. Finally in order to study the space charge distribution in thin sample we may also use the Laser Intensity Modulated Method -LIMM that has already been recently developed to work under applied voltage conditions [19].…”
Section: Space Charge Distribution Profilesmentioning
confidence: 99%
“…The Tikhonov regularization method implemented in this study proves to be reliable for calculating the space charge density profile 23 . After reconstructing the charge distribution r(z), the electric field profile E(z) can be obtained and confirmed by a thermal model calibration procedure 24 . The space charge distribution can then be determined from the derivative of the electric field.…”
Section: Limm Principlesmentioning
confidence: 99%
“…The following LIMM setup characteristics have been extensively detailed in previous research 24 . This part of the coupled system is composed of a laser diode (PMT100, 100 mW, 660 nm) which is modulated in the frequency range from 10 Hz to 10 kHz.…”
Section: Coupled Measuring Setupmentioning
confidence: 99%
“…The (F)LIMM general principle and conventional set-up have been already described in [16], whereas its modifications towards an on-line equipment were recently detailed in [17]. Figure 2 The recorded current spectra are then proceeded according a deconvolution algorithm.…”
Section: Experimental Set-up For Limm/(f)limm Measurementsmentioning
confidence: 99%