2015
DOI: 10.1016/j.sna.2015.09.017
|View full text |Cite
|
Sign up to set email alerts
|

Towards real-time and remote magnetonanothermometry with temperature accuracy better than 0.05K

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…This technique is based on the real-time measure of magnetization and magnetic susceptibility, and allows contact-less quantification of heat with high precision. It can therefore represent a first step toward real-time and accurate heat quantification in vivo, which is an essential step toward implementation of magnetic hyperthermia in clinic. , …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This technique is based on the real-time measure of magnetization and magnetic susceptibility, and allows contact-less quantification of heat with high precision. It can therefore represent a first step toward real-time and accurate heat quantification in vivo, which is an essential step toward implementation of magnetic hyperthermia in clinic. , …”
Section: Introductionmentioning
confidence: 99%
“…It can therefore represent a first step toward real-time and accurate heat quantification in vivo, which is an essential step toward implementation of magnetic hyperthermia in clinic. 36,37 Nowadays, the most commonly used and reliable systems for probing the heat of SPIONs are fiber optic cables, which can record information from the colloidal suspension. However, the results are dependent on the spatial position of the temperature sensor.…”
Section: Introductionmentioning
confidence: 99%
“…To generate a triangular magnetic field requires a triangular waveform current driving the scanner. A pre-edited input voltage [30,31] generated by the NI DAQ USB-6356 system was amplified using an AE 7548 low harmonics distortion power amplifier (AE Techron) to drive the scanner. The weak high-frequency magnetic field was generated using the solenoidal coil as well as to excite the MNPs.…”
Section: Methodsmentioning
confidence: 99%
“…Several MNTMs use magnetic nanoparticles (MNPs) where temperature is measured by employing the magnetization of MNPs in alternating current (AC) or direct current (DC) magn etic field [13][14][15][16][17][18][19]. Weaver et al found that temper ature could be determined from the ratio of the third and fifth magnetization harmonics of MNPs in an AC magn etic field [13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Weaver et al found that temper ature could be determined from the ratio of the third and fifth magnetization harmonics of MNPs in an AC magn etic field [13][14][15]. Liu et al developed methods of magnetic nanothermometry using Langevin function and DC magnetization or AC magnetization harmonics [5,6,[16][17][18][19][20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%