2022 44th Annual International Conference of the IEEE Engineering in Medicine &Amp; Biology Society (EMBC) 2022
DOI: 10.1109/embc48229.2022.9871455
|View full text |Cite
|
Sign up to set email alerts
|

Towards Micropump- and Microneedle-based Drug Delivery using Micro Transdermal Interface Platforms (MicroTIPs)

Abstract: Micro Transdermal Interface Platforms (MicroTIPs) will combine minimally invasive microneedle arrays with highly miniaturized sensors, actuators, control electronics, wireless communications and artificial intelligence. These patch-like devices will be capable of autonomous physiological monitoring and transdermal drug delivery, resulting in increased patient adherence and devolved healthcare.In this paper, we experimentally demonstrate the feasibility of controlled transdermal drug delivery using a combinatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 15 publications
(15 reference statements)
0
3
0
Order By: Relevance
“…Skin insertion tests were performed using a microneedle array and an impact inserter device. [ 34 ] Ex vivo human abdominal skin, discarded after cosmetic surgical procedures, was obtained following ethical approval by the Clinical Research Ethics Committee of the Cork Teaching Hospitals (CREC) and informed consent from all patients (approval reference ECM 4 (aa) 06/08/13). This was incubated in PBS before being clamped in a customized 3D‐printed jig for controlled stretching.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Skin insertion tests were performed using a microneedle array and an impact inserter device. [ 34 ] Ex vivo human abdominal skin, discarded after cosmetic surgical procedures, was obtained following ethical approval by the Clinical Research Ethics Committee of the Cork Teaching Hospitals (CREC) and informed consent from all patients (approval reference ECM 4 (aa) 06/08/13). This was incubated in PBS before being clamped in a customized 3D‐printed jig for controlled stretching.…”
Section: Methodsmentioning
confidence: 99%
“…The CF–MN electrode was applied to the skin sample with an impact energy of ≈0.38 J cm −2 and 5 N residual force. [ 34,36 ]…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation