2008
DOI: 10.1007/s11306-008-0104-8
|View full text |Cite
|
Sign up to set email alerts
|

Towards high-throughput metabolomics using ultrahigh-field Fourier transform ion cyclotron resonance mass spectrometry

Abstract: With unmatched mass resolution, mass accuracy, and exceptional detection sensitivity, Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) has the potential to be a powerful new technique for high-throughput metabolomic analysis. In this study, we examine the properties of an ultrahigh-field 12-Tesla (12T) FTICR-MS for the identification and absolute quantitation of human plasma metabolites, and for the untargeted metabolic fingerprinting of inbredstrain mouse serum by direct infusion (DI). U… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
107
0
3

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 136 publications
(112 citation statements)
references
References 41 publications
2
107
0
3
Order By: Relevance
“…Raw mass spectrometry data were processed using a customdeveloped software package as described elsewhere (10). First, raw mass spectra acquired from each sample group were batch processed using a home-written VBA script within the instrument vendor's data analysis software, DataAnalysis, to do automatic internal mass calibration with the reference masses of the spiked calibration standards and a known contaminant, N-butylbenzensulfonamide.…”
Section: Direct Infusion (Di)-ft-icr-msmentioning
confidence: 99%
“…Raw mass spectrometry data were processed using a customdeveloped software package as described elsewhere (10). First, raw mass spectra acquired from each sample group were batch processed using a home-written VBA script within the instrument vendor's data analysis software, DataAnalysis, to do automatic internal mass calibration with the reference masses of the spiked calibration standards and a known contaminant, N-butylbenzensulfonamide.…”
Section: Direct Infusion (Di)-ft-icr-msmentioning
confidence: 99%
“…These ESI calibrant signals allow for internal mass calibration to provide high mass accuracy with mass error of <0.5 ppm 38 . As the ESI signal of the standard "ES Tuning Mix" solution can be an order of magnitude stronger than the MALDI signals of the analytes from the tissue, the ESI-derived calibrant signals must be attenuated.…”
Section: Representative Resultsmentioning
confidence: 99%
“…When conducting MALDI MSI experiments, initial identification of the detected analytes is usually based on metabolome database searching of the measured accurate masses which are usually only available when a high resolution instrument is used 38 . The dual ESI/MALDI ion source on the Apex-Qe 12-Tesla hybrid quadrupole-FTICR mass spectrometer allows for the addition of ESI-generated signals for use as the internal mass calibrant peaks to each MALDI mass spectrum, without affecting the MALDI desorption/ionization process.…”
Section: Discussionmentioning
confidence: 99%
“…Kütle spektrometrisinin kullanımında bir diğer yaklaşım ise numunede bulunan metabolitlerin tamamının ayrılmadan kütle spektrometrisine verilmesidir. Özellikle yüksek ayrım gücüne (>1,000,000) ve kesinliğe (< 1 ppm) sahip Fourier Transform Kütle Spektrometrisi (FTMS) cihazları bu iş için kullanıldığında tatmin edici sonuçlar alınabilmektedir 28,29 . FTMS' in metabolomik çalışmalarda rutin kullanımına en büyük engel şu an için yüksek maliyeti ve dolayısıyla seyrek kullanımıdır 16 .…”
Section: Dedeksiyon Metodları Kütle Spektrometrisi (Ms)unclassified