2013
DOI: 10.1155/2013/529674
|View full text |Cite
|
Sign up to set email alerts
|

Towards Chip-Based Salinity Measurements for Small Submersibles and Biologgers

Abstract: Water’s salinity plays an important role in the environment. It can be determined by measuring conductivity, temperature, and depth (CTD). The corresponding sensor systems are commonly large and cumbersome. Here, a 7.5 × 3.5 mm chip, containing microstructured CTD sensor elements, has been developed. On this, 1.5 mm2 gold finger electrodes are used to measure the impedance, and thereby the conductivity of water, in the MHz frequency range. Operation at these frequencies resulted in higher sensitivities than th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
3

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
1
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 31 publications
0
11
0
3
Order By: Relevance
“…This is attributable to the low dilution effect of the total dissolved salts, which are presently deposited into the dam during the dry seasons. The salinity values seem to suggest that the water in the bulk of the Nandoni Dam was brackish [32,33]. A few exceptions were however noted; the water at the dam outlet and the treatment plant (the plant that sources the water from Nandoni Dam for treatment prior to distribution) indicate that this water falls within the freshwater category (i.e., salinity < 500 mg/L), although the water taste is unsatisfactory when drinking.…”
Section: Conductivity (µS/cm) Tds (Mg/l) Salinity (Mg/l)mentioning
confidence: 99%
“…This is attributable to the low dilution effect of the total dissolved salts, which are presently deposited into the dam during the dry seasons. The salinity values seem to suggest that the water in the bulk of the Nandoni Dam was brackish [32,33]. A few exceptions were however noted; the water at the dam outlet and the treatment plant (the plant that sources the water from Nandoni Dam for treatment prior to distribution) indicate that this water falls within the freshwater category (i.e., salinity < 500 mg/L), although the water taste is unsatisfactory when drinking.…”
Section: Conductivity (µS/cm) Tds (Mg/l) Salinity (Mg/l)mentioning
confidence: 99%
“…The research work done (Bhat 2005;Gadani et al 2012;Huber et al 2000;Jonsson et al 2013;Le Vine et al 2010;Men et al 2008;Rahman et al 2011;Reul et al 2014;Scudiero et al 2012) based on the monitoring and evaluation of salinity involves certain demerits that deters them to be used on an industrial scale. Some sensors like that optical ones are used to measure the salinity (Huber et al 2000) for a concentration from 200 mM to 2M.…”
Section: Salinity Sensingmentioning
confidence: 99%
“…Thus, it is state of the art to fabricate a lowcost, efficient sensing system that can be used to determine the changes in the salinity level to apply immediate remedial measures. Some of the other impedance measurement systems that have been proposed earlier (Jonsson et al 2013) have certain demerits like low sensitivity and a complicated embedded system that need time and expertise to be operated. The sensors that are being developed with MEMS technology have a high fabrication cost.…”
Section: Salinity Sensingmentioning
confidence: 99%
“…This is attributable to the low dilution effect of the total dissolved salts, which are presently deposited into the dam during the dry seasons. The salinity values seem to suggest that the water in the bulk of the Nandoni Dam was brackish [31,32]. A few exceptions were however noted; the water at the dam outlet and the treatment plant (the plant that sources the water from Nandoni dam for treatment prior to distribution) indicate that this water falls within the freshwater category (i.e.…”
Section: Physico-chemical Analysismentioning