2015
DOI: 10.1016/j.bioelechem.2015.05.014
|View full text |Cite
|
Sign up to set email alerts
|

Towards a blocking-free electrochemical immunosensing strategy for anti-transglutaminase antibodies using screen-printed electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 45 publications
0
13
0
Order By: Relevance
“…We aimed to apply our previous assay [ 28 ] to the 8-channel array of electrodes in order to perform multiple simultaneous analysis. This array of electrodes has been successfully employed in numerous applications based on electrochemical biosensors [ 10 , 11 , 12 , 13 , 14 , 15 , 29 , 30 ] while presenting their great advantages such as low sample requirement and easy implementation to point of care (PoC) system. The characterization of the carbon nanofiber enriched electrodes has been given in earlier reports [ 28 , 31 , 32 , 33 ].…”
Section: Resultsmentioning
confidence: 99%
“…We aimed to apply our previous assay [ 28 ] to the 8-channel array of electrodes in order to perform multiple simultaneous analysis. This array of electrodes has been successfully employed in numerous applications based on electrochemical biosensors [ 10 , 11 , 12 , 13 , 14 , 15 , 29 , 30 ] while presenting their great advantages such as low sample requirement and easy implementation to point of care (PoC) system. The characterization of the carbon nanofiber enriched electrodes has been given in earlier reports [ 28 , 31 , 32 , 33 ].…”
Section: Resultsmentioning
confidence: 99%
“…In principle, such barcodes could be used for the simultaneous detection of thousands of biomarkers using computational deconvolution. The most widespread practice in detecting QDs is through ASV proceeded by acid digestion [ 82 , 83 ]. Merkoci et al were among the first to demonstrate a less aggressive strategy by direct detection of CdS through the redox cycling of Cd (II).…”
Section: Immunoassay Techniques For Printed Electrodesmentioning
confidence: 99%
“…Other interesting electrochemical immunosensors for the detection of anti-tTG IgA and anti-tTG IgG in human serum samples were developed by Martin-Yerga et al [49,50]. An array of 8-channel SPEs was used as transducer and modified with tTG by adsorption.…”
Section: No Label-free Innovative Electrochemical Immunosensorsmentioning
confidence: 99%