2022
DOI: 10.1016/j.radphyschem.2022.110046
|View full text |Cite
|
Sign up to set email alerts
|

Toward three-dimensional patient-specific internal dosimetry using GATE Monte Carlo technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“…The mean intensity over volume is a significant factor in justice activity variation over time, without biochemical knowledge. From a dosimetry point of view, Monte Carlo and voxel S value-based (VSV) are the main and most accurate methods used to determine the S-value in which dose maps and cumulative activity maps can be estimated according to patient image analysis [10]. There is a fact that crude knowledge and obstacle protocols above this method have hampered the progress and its clinical usage, but there is abundant room for development and analysis of the procedure.…”
Section: Introductionmentioning
confidence: 99%
“…The mean intensity over volume is a significant factor in justice activity variation over time, without biochemical knowledge. From a dosimetry point of view, Monte Carlo and voxel S value-based (VSV) are the main and most accurate methods used to determine the S-value in which dose maps and cumulative activity maps can be estimated according to patient image analysis [10]. There is a fact that crude knowledge and obstacle protocols above this method have hampered the progress and its clinical usage, but there is abundant room for development and analysis of the procedure.…”
Section: Introductionmentioning
confidence: 99%
“…The threshold for producing secondary particles was set to 2.0 mm and the inputs for the seTLE actor were set with the commands enableHybridino false, setPrimaryMultiplicity 100, and setSecondaryMultiplicity 1. Using regression, the trend curve formulas were obtained and evaluated to calculate the simulation time with relative uncertainty at 10% (Karimipourfard et al 2022). Simulations with and without VRTs were performed at 6.1 min and 1176.0 min respectively for the lutetium-177 source, and 5.4 min and 7700.0 min respectively for the radium-223 source.…”
Section: Resultsmentioning
confidence: 99%
“…The 3D S‐factor map was generated using a MATLAB script considering labeled CT images of the organs. The statistical uncertainties of the dose rates were estimated to be less than 0.1% at the voxel level 29,30 …”
Section: Methodsmentioning
confidence: 97%
“…The statistical uncertainties of the dose rates were estimated to be less than 0.1% at the voxel level. 29,30 To evaluate the impact of the segmentation method, the GATE MC simulator was employed. The two aforementioned DL approaches were compared with manual segmentation.…”
Section: Impact Of DL Methods On the Organ's S-valuementioning
confidence: 99%
See 1 more Smart Citation