2015
DOI: 10.1016/j.pharep.2015.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Toward selective detection of reactive oxygen and nitrogen species with the use of fluorogenic probes – Limitations, progress, and perspectives

Abstract: Over the last forty years, there has been tremendous progress in understanding the biological reactions of reactive oxygen species (ROS) and reactive nitrogen species (RNS). It is widely accepted that the generation of ROS and RNS is involved in physiological and pathophysiological processes. To understand the role of ROS and RNS in a variety of pathologies, the specific detection of ROS and RNS is fundamental. Unfortunately, the intracellular detection and quantitation of ROS and RNS remains a challenge. In t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
63
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 58 publications
(64 citation statements)
references
References 71 publications
1
63
0
Order By: Relevance
“…It should be emphasized that oxidants other than H 2 O 2 (e.g., hypohalous ions and nucleophilic peroxides) can also oxidize boronates to corresponding phenols so reaction is not specific for H 2 O 2 (Chart 27). 246,276,283 …”
Section: Mitochondria-targeted Probes and Sensors For Reactive Oxymentioning
confidence: 99%
See 1 more Smart Citation
“…It should be emphasized that oxidants other than H 2 O 2 (e.g., hypohalous ions and nucleophilic peroxides) can also oxidize boronates to corresponding phenols so reaction is not specific for H 2 O 2 (Chart 27). 246,276,283 …”
Section: Mitochondria-targeted Probes and Sensors For Reactive Oxymentioning
confidence: 99%
“…246,252,284286,295,296 Use of the o -MitoPhB(OH) 2 probe should allow the production of peroxynitrite and H 2 O 2 inside mitochondria of living animals systems to be monitored, by measuring the amounts of o -MitoPhOH and cyclo - o -MitoPh products with LC-MS/MS. 286 In addition, hypohalous (HOCl) or hypobromous (HOBr)-specific products also can be formed (Chart 31).…”
Section: Mitochondria-targeted Probes and Sensors For Reactive Oxymentioning
confidence: 99%
“…[3] Arylboronic acids and their esters are oxidized to phenols with ak inetic selectivity of ca. [4,5] CÀBb ond oxidation of arylboronates by ROSh as also been widely used as at rigger in programmed depolymerization, sensing amplification, drug delivery,and theragnostics. [3a] Nevertheless,c laims of selectivity for each of these ROS have been reported in solution assays and cell imaging experiments.…”
mentioning
confidence: 99%
“…There are also a number of useful review articles published including guidelines how to use the traditional (and the new) assays for RONS detection, highlighting the specific pitfalls and drawbacks of them [28][29][30][31][32].…”
Section: Usefulness Of Traditional Rons Detection Assaysmentioning
confidence: 99%
“…using specific boronate probes [30]. Also fluorescein boronate probe was reported as a suitable assay for quantification of cell-derived peroxynitrite in endothelial cells and parasite-activated macrophages [141].…”
Section: No the Reaction Ofmentioning
confidence: 99%