2016
DOI: 10.1007/s10334-016-0561-4
|View full text |Cite
|
Sign up to set email alerts
|

Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale

Abstract: An initiative to design and build magnetic resonance imaging (MRI) and spectroscopy (MRS) instruments at 14 T and beyond to 20 T has been underway since 2012. This initiative has been supported by 22 interested participants from the USA and Europe, of which 15 are authors of this review. Advances in high temperature superconductor materials, advances in cryocooling engineering, prospects for non-persistent mode stable magnets, and experiences gained from large-bore, high-field magnet engineering for the nuclea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
51
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(52 citation statements)
references
References 133 publications
0
51
0
1
Order By: Relevance
“…There is evidence that physiological effects, such as vertigo, metallic taste, and dizziness are related to the spatial fall-off ( dB 0 / dz ) of the fringe field and to the diamagnetic force B 0 * dB 0 / dz (Kangarlu et al, 1999; Liu et al, 2003; Cavin et al, 2007; Glover et al, 2007; Glover and Bowtell, 2008; Groebner et al, 2011; Budinger et al, 2016). …”
Section: Other Noteworthy Challenges Related To Uhf Technologymentioning
confidence: 99%
“…There is evidence that physiological effects, such as vertigo, metallic taste, and dizziness are related to the spatial fall-off ( dB 0 / dz ) of the fringe field and to the diamagnetic force B 0 * dB 0 / dz (Kangarlu et al, 1999; Liu et al, 2003; Cavin et al, 2007; Glover et al, 2007; Glover and Bowtell, 2008; Groebner et al, 2011; Budinger et al, 2016). …”
Section: Other Noteworthy Challenges Related To Uhf Technologymentioning
confidence: 99%
“…(For reviews of applications of high magnetic fields to MRI see references (8, 9). ) Here we focus on advancements in technology and methodology as applied in the burgeoning field of NMR at field strengths above 1 GHz.…”
Section: Perspectivementioning
confidence: 99%
“…research [6]. Thus, the geometrical parameters are optimized to attain a maximum B 1 and to reduce the coil dimensions (minimum Rs) so a low noise Signal could be detected.…”
Section: Implantable Microcoil For In-vivo Magnetic Resonance Spectromentioning
confidence: 99%