2020
DOI: 10.1016/j.sab.2020.105856
|View full text |Cite
|
Sign up to set email alerts
|

Total-reflection X-ray fluorescence spectrometry as a tool for the direct elemental analysis of ores: Application to iron, manganese, ferromanganese, nickel-copper sulfide ores and ferromanganese nodules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 23 publications
0
14
0
Order By: Relevance
“…TXRF can be applied for direct analysis of iron, manganese, ferromanganese, nickel-copper sulfide ores, oceanic and lacustrine nodules [Pashkova et al, 2020;Akhmetzhanov et al, 2021;Chubarov et al, 2021]. The suspension preparation (5 mL of 1 % Triton X-100 solution and 20 mg of fine powder with a size <10 μm and internal standard of Ga) gives a possibility for fast reliable determination of major and minor elements by the internal standard method with the recovery values 75-125 %.…”
Section: Application Of Txrf To Geological Objectsmentioning
confidence: 99%
See 3 more Smart Citations
“…TXRF can be applied for direct analysis of iron, manganese, ferromanganese, nickel-copper sulfide ores, oceanic and lacustrine nodules [Pashkova et al, 2020;Akhmetzhanov et al, 2021;Chubarov et al, 2021]. The suspension preparation (5 mL of 1 % Triton X-100 solution and 20 mg of fine powder with a size <10 μm and internal standard of Ga) gives a possibility for fast reliable determination of major and minor elements by the internal standard method with the recovery values 75-125 %.…”
Section: Application Of Txrf To Geological Objectsmentioning
confidence: 99%
“…One of the problems of TXRF analysis is strong peaks overlapping due to poor spectral resolution of the energy-dispersive spectrum. For instance, the differences between the TXRF results and the certified values in CRMs may be more than 30 % for As, Pb, V, Cr, Ba in the nodules due to PbLα/AsKα, BaLα/TiKα, CrKα/VKβ, VKα/TiKβ lines overlapping [Pashkova et al, 2020;Chubarov et al, 2021]. Chemometric approaches may be used to solve this problem [Akhmetzhanov et al, 2021].…”
Section: Application Of Txrf To Geological Objectsmentioning
confidence: 99%
See 2 more Smart Citations
“…Reference [16] analyze ore samples using total-reflection X-ray fluorescence spectrometry. The authors demonstrate that it is possible to reduce the sampling error by decreasing the particle size in the sample.…”
Section: Literature Reviewmentioning
confidence: 99%