2021
DOI: 10.1302/0301-620x.103b7.bjj-2020-2443.r1
|View full text |Cite
|
Sign up to set email alerts
|

Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger

Abstract: Aims Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
16
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(31 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…The current study found mean wear rates for XLPE were towards the more favourable end of the range of 0.02 mm/year to 0.07 mm/year wear rates in previous studies. 4,7,10,13,22-2431-35 This may be attributable to our study using first-year radiographs as reference films to allow for creep deformation, excluding patients undergoing revision surgery from the final wear analysis, and using a standardized surgical technique in all patients to limit confounders such as acetabular component design, polyethylene geometry, femoral head diameter, femoral head geometry, and stem design. Roedel et al 4 reviewed outcomes in 87 patients aged under 50 years undergoing THA with XLPE, and reported that the mean polyethylene liner wear rate was 0.04 mm/year at 15 years’ follow-up.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The current study found mean wear rates for XLPE were towards the more favourable end of the range of 0.02 mm/year to 0.07 mm/year wear rates in previous studies. 4,7,10,13,22-2431-35 This may be attributable to our study using first-year radiographs as reference films to allow for creep deformation, excluding patients undergoing revision surgery from the final wear analysis, and using a standardized surgical technique in all patients to limit confounders such as acetabular component design, polyethylene geometry, femoral head diameter, femoral head geometry, and stem design. Roedel et al 4 reviewed outcomes in 87 patients aged under 50 years undergoing THA with XLPE, and reported that the mean polyethylene liner wear rate was 0.04 mm/year at 15 years’ follow-up.…”
Section: Discussionmentioning
confidence: 99%
“…4,7,10,13,22-2431-35 This may be attributable to our study using first-year radiographs as reference films to allow for creep deformation, excluding patients undergoing revision surgery from the final wear analysis, and using a standardized surgical technique in all patients to limit confounders such as acetabular component design, polyethylene geometry, femoral head diameter, femoral head geometry, and stem design. Roedel et al 4 reviewed outcomes in 87 patients aged under 50 years undergoing THA with XLPE, and reported that the mean polyethylene liner wear rate was 0.04 mm/year at 15 years’ follow-up. The higher wear rates may be attributable to the study having a younger and more active cohort of patients, implantation of different femoral head sizes, and longer follow-up times compared to our study.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations