2016
DOI: 10.1186/s13014-016-0625-7
|View full text |Cite
|
Sign up to set email alerts
|

Total body irradiation with volumetric modulated arc therapy: Dosimetric data and first clinical experience

Abstract: Background: To implement total body irradiation (TBI) using volumetric modulated arc therapy (VMAT). We applied the Varian RapidArc™ software to calculate and optimize the dose distribution. Emphasis was placed on applying a homogenous dose to the PTV and on reducing the dose to the lungs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
75
0
4

Year Published

2017
2017
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 71 publications
(84 citation statements)
references
References 24 publications
5
75
0
4
Order By: Relevance
“…The hottest dose to 2 cc of the volume was recorded and dose homogeneity index was calculated for the VMAT plans using D 90% /D 10% . D 2 cc doses of up to 130% and the dose homogeneity index within 10% were in keeping with results reported by other modulated VMAT techniques 14, 24. Although no strict limit is set on D 2 cc or the dose homogeneity, regions of hotspots are evaluated based on their location in the patient.…”
Section: Discussionsupporting
confidence: 84%
See 1 more Smart Citation
“…The hottest dose to 2 cc of the volume was recorded and dose homogeneity index was calculated for the VMAT plans using D 90% /D 10% . D 2 cc doses of up to 130% and the dose homogeneity index within 10% were in keeping with results reported by other modulated VMAT techniques 14, 24. Although no strict limit is set on D 2 cc or the dose homogeneity, regions of hotspots are evaluated based on their location in the patient.…”
Section: Discussionsupporting
confidence: 84%
“…Previous studies have demonstrated the use of Varian RapidArc in combination with the Eclipse TPS23 with promising results in the first clinical cases 24. A VMAT approach to TBI treatments has the potential to make TBI accessible to more clinical departments where equipment limitations or bunker size has restricted implementation.…”
Section: Introductionmentioning
confidence: 99%
“…This includes the use of volumetric modulated arc therapy (VMAT), which has shown promise in improving dose homogeneity and reducing the dose to organs at risk (OAR). Springer et al developed a 9‐15 isocenter VMAT technique where the patient is longitudinally translated to capture the entire planning target volume (PTV) in eight segments . Smooth junctions between segments were achieved using inverse planning, resulting in a homogeneous dose delivery.…”
Section: Introductionmentioning
confidence: 99%
“…Helical tomotherapy (HT) based methods have been used for TMI/TMLI2, 3, 4, 5 as well as TBI 5, 6, 7. Using conventional linacs, intensity modulated radiotherapy (IMRT) TMI delivery proved feasible,8, 9 however, the predominant linac approach utilizes volumetric modulated arc therapy (VMAT) using Varian RapidArc (Varian Medical Systems, Palo Alto, CA, USA) 10, 11, 12, 13, 14, 15, 16, 17…”
Section: Introductionmentioning
confidence: 99%
“…Previous VMAT TBI and TMI/TMLI studies have utilized a variety of dose verification techniques. Portal imaging,13 Mapcheck,14 thermoluminescent dosimeters (TLDs) in an anthropomorphic phantom,15 ionization chamber array (Octavius)16 and diode array (ArcCHECK) 17. Junction measurements are seldom reported on.…”
Section: Introductionmentioning
confidence: 99%