2020
DOI: 10.1021/acsomega.0c04426
|View full text |Cite
|
Sign up to set email alerts
|

Torrefaction at 200 °C of Pubescens Pretreated with AlCl3 Aqueous Solution at Room Temperature

Abstract: Metal salt soaking–torrefaction conversion technology was investigated. It was found that AlCl 3 pretreatment of pubescens favored observably the yield of liquid and small-molecular products in torrefaction via changing the composition and structure of the raw material. The maximum conversion of pretreated samples, washed (PSW) and Y liquid were 15.5 and 10.8 wt % (with 0.26 wt % monosaccharides, 0.26 wt % carboxylic acids, 0.38 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 59 publications
0
7
0
Order By: Relevance
“…GC-TCD was used to determine the relative contents of gaseous products, which were collected by a gas bag during the whole pyrolysis process. The samples were tested by GC9710 (Fuli) equipped with a TCD detector and a TDX-1 carbon molecular sieve packed column (2 m × 3 mm id) [ 52 ]. The main chromatographic parameters were as follows: carrier gas, nitrogen; carrier gas flow rate, 20 mL/min; inlet temperature, 145 °C; column temperature, 120 °C; detector temperature, 180 °C.…”
Section: Methodsmentioning
confidence: 99%
“…GC-TCD was used to determine the relative contents of gaseous products, which were collected by a gas bag during the whole pyrolysis process. The samples were tested by GC9710 (Fuli) equipped with a TCD detector and a TDX-1 carbon molecular sieve packed column (2 m × 3 mm id) [ 52 ]. The main chromatographic parameters were as follows: carrier gas, nitrogen; carrier gas flow rate, 20 mL/min; inlet temperature, 145 °C; column temperature, 120 °C; detector temperature, 180 °C.…”
Section: Methodsmentioning
confidence: 99%
“…Meanwhile, the detector voltage of instrument was 1.60 kV. The collision-induced dissociation (CID) energy for MS/MS was 25% [20]. Before the test, a small amount of bio-oil was obtained with a capillary pipet and then diluted by methanol to about 2 mL.…”
Section: Characterization Of the Liquid Productsmentioning
confidence: 99%
“…GC-TCD was used to determine the relative contents of gaseous products. The samples were tested by GC9710 (Fuli, Taizhou, China) equipped with a TCD detector and a TDX-1 carbon molecular sieve packed column (2 m × 3 mm id) [20]. The temperatures of column, detector and oven were maintained at 120, 145 and 160 • C, respectively.…”
Section: Characterization Of the Gaseous Productsmentioning
confidence: 99%
See 2 more Smart Citations