2018
DOI: 10.1007/s00158-018-1966-7
|View full text |Cite
|
Sign up to set email alerts
|

Topology optimization applied to the development of small scale pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 26 publications
0
11
0
Order By: Relevance
“…In adsorption systems, it is verified that topology optimisation presented improvements when distributing different materials inside the system . The reliability of the obtained solutions was also verified experimentally (Sá et al 2018).…”
Section: Introductionmentioning
confidence: 66%
“…In adsorption systems, it is verified that topology optimisation presented improvements when distributing different materials inside the system . The reliability of the obtained solutions was also verified experimentally (Sá et al 2018).…”
Section: Introductionmentioning
confidence: 66%
“…Jensen [61] proposed to use anisotropic mesh adaptation for density-based optimisation of Stokes flow, demonstrating that this allows for efficiently resolving the physical length scale related to very high Brinkman penalisation terms. Sá et al [62] applied density-based optimisation to the design of a small scale rotary pump considering both energy dissipation and vorticity with experimental verification of the design performance. Zhou et al [63] presented an integrated shape morphing and topology optimisation approach based on a mesh handling methodology called a deformable simplicial complex (DSC).…”
Section: Steady Laminar Flowmentioning
confidence: 99%
“…Only 12 papers, or 7%, contain some form of experimental investigation of the topology-optimised designs. These cover fixed-geometry fluid diodes [43,68], small scale rotary pumps [62], forced convection heat sinks [116,128,141,146], passive coolers for light-emitting diode lamps [154,155], porous bioreactors [186], particle separators [102], and conformal cooling channels [142].…”
Section: Experimental Validationmentioning
confidence: 99%
“…However, the experiments are performed with water. Results considering the same methodology applied to Newtonian laminar flow are published in the work Sá et al (2018).…”
Section: Resultsmentioning
confidence: 99%
“…Two prototypes, with different drivers, are built. The first had a slide bearing and considered optimized impellers for water (Newtonian fluid) and laminar flow and is published in the work Sá et al (2018). The second considers the magnetic levitation for the bearing and uses the optimized topologies obtained in this work for blood (non-Newtonian fluid) and turbulent flow.…”
Section: Experimental Methodologymentioning
confidence: 99%