Topochemical Speciation of Intercalated Palladium in Graphite by Valence Band X-ray Spectrometry in the Electron Microprobe

Abstract: The binding state of palladium was studied within the frame of an investigation on the mechanism of analyte fixation during the pyrolysis step in graphite furnace atomic spectrometry. One approach was the determination of the palladium intercalated in the pyrolytic coating of the graphite tube. Due to the low concentrations of intercalated palladium in the pyrolytic coating, precise determination of the shift of certain X-ray lines was chosen. From several investigated valence state sensitive X-ray transitions… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 45 publications
0
3
0
Order By: Relevance
“…25 Recently it was successfully attempted to apply this method to palladium. 26 Due to the relative reduction of the line shift with rising atomic number it was necessary to devise a new method for the expected very small shifts of Pd. This method is based on the fact that a peak shift leads to a pronounced change of intensity in the flanks of the peak.…”
Section: Electron Probe Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…25 Recently it was successfully attempted to apply this method to palladium. 26 Due to the relative reduction of the line shift with rising atomic number it was necessary to devise a new method for the expected very small shifts of Pd. This method is based on the fact that a peak shift leads to a pronounced change of intensity in the flanks of the peak.…”
Section: Electron Probe Techniquesmentioning
confidence: 99%
“…25 It was then consequently developed further by us. 26 This method is based on the concomitant changes of both, the intensity ratio and the wavelength shifts of the Fe L a and Fe L b X-ray emission lines with variations of the Fe 2+ to Fe 3+ -ratio. 25 If such measurements are carried out by the use of synchrotron radiation, a lateral resolution level of a few micrometers can be reached together with a high detection sensitivity.…”
Section: Electron Probe Techniquesmentioning
confidence: 99%
“…Here both Pd, W, Rh, Ir, Nb, Ni, Zr, and Mg salts or binary mixtures of them can be used to retain the analytes while evaporating the matrix elements. In efforts to clarify the mechanisms of these modifiers, Rohr et al (22) investigated whether intercalation of Pd in the graphite occurs with the aid of valence bond X-ray spectrometry. Maia et al (23) investigated the use of a permanently modified graphite tube surface to eliminate interferences in coal analysis, whereas Fischer (24) studied the electrothermal atomization of Pdstabilized Se in the presence of phosphate.…”
mentioning
confidence: 99%