2005
DOI: 10.1002/lsm.20229
|View full text |Cite
|
Sign up to set email alerts
|

Tooth caries detection by curve fitting of laser‐induced fluorescence emission: A comparative evaluation with reflectance spectroscopy

Abstract: Nitrogen laser-excited fluorescence spectral studies were found to be more suited for detection of caries lesions. The LIF measurement with spectral analysis, done by curve fitting, outscores the diffuse reflectance methodology and shows the potential to screen different levels of tooth decay in a clinical setting.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0
3

Year Published

2007
2007
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(16 citation statements)
references
References 19 publications
0
13
0
3
Order By: Relevance
“…It could be very interesting develop other experiment using different pulse width at near infrared spec-tral band, indeed submitting to a detection by fluorescence spectroscopy, as some papers have demonstrated [20,21].…”
Section: Discussionmentioning
confidence: 99%
“…It could be very interesting develop other experiment using different pulse width at near infrared spec-tral band, indeed submitting to a detection by fluorescence spectroscopy, as some papers have demonstrated [20,21].…”
Section: Discussionmentioning
confidence: 99%
“…Transversal microradiography 1 uses a microfocus x-ray source and thus is difficult to apply to in vivo diagnosis. Digital imaging fiber-optic transillumination 2 and other methods based on fluorescence observation, such as quantitative light-induced fluorescence 2,3 and infrared-laser or visible lightinduced fluorescence, 4,5 have been well established. Moreover, some diagnostic systems based on them are commercially available.…”
Section: Introductionmentioning
confidence: 99%
“…Однако при этом области твердой ткани зуба с патологией могут быть выявлены лишь на стадии " белого пятна" и позднее, что оставляет открытыми вопросы об интерпретации полезного сигнала, а так-же своевременной диагностике природы заболевания. Поэтому в последнее время активно разрабатываются и находят клиническое применение различные диагно-стические устройства, принцип действия которых ос-нован на оценке сигнала ФЛ от твердых тканей зу-ба [14,[17][18][19][20][21]. Обработанный программным комплексом ФЛ сигнал позволяет визуализировать картину пора-женной области.…”
unclassified