TMS-induced artifacts on EEG can be reduced by rearrangement of the electrode’s lead wire before recording

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
58
0
2

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 73 publications
(62 citation statements)
references
References 18 publications
2
58
0
2
Order By: Relevance
“…Смещение электродов под действием электродви-жущих сил [20], вибрация катушки при каждом им-пульсе [3] и сокращения мышц -все это приводит к артефактам на ЭЭГ. В связи с этим при проведении записи ТМС-ЭЭГ рекомендуется надевать на голову испытуемого поверх электродов тонкую шапочку, что минимизирует смещение электродов при располо-жении над ними стимуляционной катушки.…”
Section: том 7 Volunclassified
See 1 more Smart Citation
“…Смещение электродов под действием электродви-жущих сил [20], вибрация катушки при каждом им-пульсе [3] и сокращения мышц -все это приводит к артефактам на ЭЭГ. В связи с этим при проведении записи ТМС-ЭЭГ рекомендуется надевать на голову испытуемого поверх электродов тонкую шапочку, что минимизирует смещение электродов при располо-жении над ними стимуляционной катушки.…”
Section: том 7 Volunclassified
“…При мно-гоканальной ЭЭГ важно избегать создания петель на проводах, для этого провода от сен-соров следует группировать вместе и макси-мально удалять от силового кабеля стимуляци-онной катушки [4]. Также рекомендуется ориентировать провода перпендикулярно по отношению к ТМС-индуцированному электрическому полю, например, в случае ис-пользования восьмиобразной катушки опти-мальное расположение проводов будет пер-пендикулярно ручке катушки [20].…”
Section: том 7 Volunclassified
“…A study conducted by Julkunen and colleagues, for example, found a significant reduction of TMS-induced artefacts after puncturing the epithelium under the electrode contacts with custom-made needles [80]. Finally, recent studies have observed that the electrode wire arrangement can also play an important role in reducing TMS-evoked artefacts (e.g., [69,81]). Sekiguchi and coworkers, in particular, tested the effect of coil direction relative to the orientation of the stimulated electrode wire [81].…”
Section: Technical Issuesmentioning
confidence: 99%
“…Finally, recent studies have observed that the electrode wire arrangement can also play an important role in reducing TMS-evoked artefacts (e.g., [69,81]). Sekiguchi and coworkers, in particular, tested the effect of coil direction relative to the orientation of the stimulated electrode wire [81]. The authors observed a great reduction in the artefact amplitude when the coil was placed perpendicularly to the wire direction of the stimulated electrode.…”
Section: Technical Issuesmentioning
confidence: 99%
“…The magnetic pulse of TMS affects the muscles and motor nerves underneath the coil causing the muscle activation and eye movement, which results in the induction of EEG artifacts. The magnetic pulse of TMS can also excite the somatosensory nerve endings and the coil click activates the auditory system of the subject, which can be seen in EEG as auditory or somatosensory evoked potentials [15]. The effect of artifacts can be attenuated by deleting data with amplitudes over a certain value.…”
Section: Introductionmentioning
confidence: 99%