1989
DOI: 10.1016/0950-0618(89)90007-x
|View full text |Cite
|
Sign up to set email alerts
|

Titanium based mesh anode in the catholic protection of reinforcing bars in concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

1999
1999
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…To effectively apply an ICCP technique in practice, it is critical to choose an anode material with a high-performance capacity in a concrete system, especially for high-resistivity reinforced concrete [ 4 ]. Current research on anode materials, optimizing for polarization behavior and cost, generally focuses on thermally sprayed zinc [ 5 ], titanium anodes [ 6 , 7 ], titanium mesh anodes [ 8 ], coating-overlay anodes [ 9 ], and conductive paints [ 10 ]. However, they have several drawbacks and are not well adopted in fields.…”
Section: Introductionmentioning
confidence: 99%
“…To effectively apply an ICCP technique in practice, it is critical to choose an anode material with a high-performance capacity in a concrete system, especially for high-resistivity reinforced concrete [ 4 ]. Current research on anode materials, optimizing for polarization behavior and cost, generally focuses on thermally sprayed zinc [ 5 ], titanium anodes [ 6 , 7 ], titanium mesh anodes [ 8 ], coating-overlay anodes [ 9 ], and conductive paints [ 10 ]. However, they have several drawbacks and are not well adopted in fields.…”
Section: Introductionmentioning
confidence: 99%
“…However, the major challenge is throwing power, which is a distance that current can be supplied. In many studies, the SACP system showed that the distance is limited to a few ten centimeters, which is mainly dependent on the concrete resistivity [8]. Thus, it is difficult to protect entire structure by menas of the SACP since the structure tends to be more larger and complex.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, this study focuses on the relationship between anode types for ICCP system and CP performance on reinforced concrete. Comparitive study with laboratory experiments was carried out on reinforced concrete specimens with 3 different types of commercial anodes for the ICCP system to compare the performance of each anode [8,9,10].…”
Section: Introductionmentioning
confidence: 99%