2007
DOI: 10.1016/j.actbio.2006.10.010
|View full text |Cite
|
Sign up to set email alerts
|

Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
87
0
26

Year Published

2008
2008
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 147 publications
(118 citation statements)
references
References 31 publications
1
87
0
26
Order By: Relevance
“…Studies on mice showed that within the first day after an intra-venous injection of vanadium, the highest levels were found in the kidney 37) . Urinary excretion is the main elimination pathway for injected vanadium in humans 5,39) . However, in some situations, Al and V will not be detected on the superficial surface of the anodic oxide layer, as both elements are below the detection limit as confirmed by XPS in the present study.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Studies on mice showed that within the first day after an intra-venous injection of vanadium, the highest levels were found in the kidney 37) . Urinary excretion is the main elimination pathway for injected vanadium in humans 5,39) . However, in some situations, Al and V will not be detected on the superficial surface of the anodic oxide layer, as both elements are below the detection limit as confirmed by XPS in the present study.…”
Section: Discussionmentioning
confidence: 99%
“…As commercially pure titanium (CP-Ti) has relatively lower fatigue strength, titanium alloys such as Ti6Al4V have widely been used to overcome this disadvantage of CP-Ti for heavy load [5][6][7] . Titanium and its alloys have been used for implantation in dentistry and orthopedic medicine, because these materials can form a direct interface between an implant and bone without intervening soft tissue, in so-called "osseointegration".…”
Section: Introductionmentioning
confidence: 99%
“…Dilek et al 8 relataram torques de remoção mais elevados que os de inserção, em ensaio não-vital em fêmur bovino, discordando dos outros estudos. Torques mais elevados de remoção do que de inserção são encontrados em estudos in vivo, quando há um acompanhamento de, pelo menos, 4 semanas, permitindo a osteointegração do dispositivo 5,6,16,17,18 . Durante os ensaios de inserção, dois mini-implantes dos grupos NSP e NCP fraturaram e os outros três do grupo NCP fraturaram durante os ensaios de remoção.…”
Section: Discussionunclassified
“…Existem poucos estudos avaliando o torque máximo de remoção. Geralmente, os torques de remoção, em estudos de curto prazo, são inferiores aos torques de inserção 9,16 . No entanto, quando existe um período de acompanhamento de mais de 4 semanas, os torques de remoção aumentam significativamente 5,6,8 .…”
Section: Introductionunclassified
“…both exhibit good bioactivity. Unfortunately, these bioactive ceramic materials are not suitable for load-bearing conditions on account of their poor mechanical properties Morais et al, 2007). As compared to these brittle ceramics, metal materials such as titanium and its alloys exhibit excellent mechanical toughness and strength .…”
Section: Introductionmentioning
confidence: 99%