eCM 2009
DOI: 10.22203/ecm.v018a04
|View full text |Cite
|
Sign up to set email alerts
|

Tissue reaction to implants of different metals: A study using guide wires in cannulated screws

Abstract: Cannulated screws, along with guide wires, are typically used for surgical fracture treatment in cancellous bone. Breakage or bending deformation of the guide wire is a clinical concern. Mechanically superior guide wires made of Co-Cr alloys such as MP35N and L605 may reduce the occurrence of mechanical failures when used in combination with conventional (316L stainless steel) cannulated screws. However the possibility of galvanic or crevice corrosion and adverse tissue reaction, exists when using dissimilar m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 17 publications
(25 reference statements)
0
10
0
Order By: Relevance
“…The plates were placed in close proximity to each other and frequently had screws in contact with each other inside the canal or almost touching each other on the cortex. The major concern, as reported in prior studies, 6,7,14,16,17 is when the metals (stainless steel plate and titanium screw) are in direct contact with each other. The concern in the current study was that the implants of dissimilar metals were in close proximity on the same bone in the same biological milieu, which posed a concern for the possibility of galvanic corrosion.…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…The plates were placed in close proximity to each other and frequently had screws in contact with each other inside the canal or almost touching each other on the cortex. The major concern, as reported in prior studies, 6,7,14,16,17 is when the metals (stainless steel plate and titanium screw) are in direct contact with each other. The concern in the current study was that the implants of dissimilar metals were in close proximity on the same bone in the same biological milieu, which posed a concern for the possibility of galvanic corrosion.…”
Section: Discussionmentioning
confidence: 94%
“…6 Another study showed that when a broken guidewire made of stainless steel was left in direct contact with a titanium screw in vivo in an animal model, no cellular response occurred. 17 The current authors are not aware of any studies to date that have evaluated the effects of the use of dissimilar metals in vivo.…”
Section: Discussionmentioning
confidence: 99%
“…The intimacy of bone contact with the implants at six months suggest that despite the use of dissimilar materials in this cannulated screw and guide wire construct, the local environment provided stable implant anchorage as well as acceptable biotolerance [9]. …”
Section: Discussionmentioning
confidence: 99%
“…However, there have been studies [4,5] that refute this concern and show that no adverse in vivo effects were detected with the use of dissimilar materials in a model of stainless steel wire and titanium screw. However, there have been studies [4,5] that refute this concern and show that no adverse in vivo effects were detected with the use of dissimilar materials in a model of stainless steel wire and titanium screw.…”
Section: Intra-operative K-wire Breakage During Odontoid Screw Fi Xationmentioning