2022
DOI: 10.1007/s10008-021-05101-x
|View full text |Cite
|
Sign up to set email alerts
|

TiO2/CuInS2-sensitized structure for sensitive photoelectrochemical immunoassay of cortisol in saliva

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 47 publications
1
3
0
Order By: Relevance
“…The presence of the microrobots leads to a notable increase of the SPE’s R ct due to the low conductivity of the semiconducting TiO 2 , which represents the main constituent of the microrobots 66 . This behavior has also been observed after TiO 2 loading on FTO electrodes 67 . The R ct further rises due to the lower microrobots’ conductance in consequence of the inclusion of a large quantity of non-conducting polystyrene nanoparticles 68 .…”
Section: Resultssupporting
confidence: 63%
“…The presence of the microrobots leads to a notable increase of the SPE’s R ct due to the low conductivity of the semiconducting TiO 2 , which represents the main constituent of the microrobots 66 . This behavior has also been observed after TiO 2 loading on FTO electrodes 67 . The R ct further rises due to the lower microrobots’ conductance in consequence of the inclusion of a large quantity of non-conducting polystyrene nanoparticles 68 .…”
Section: Resultssupporting
confidence: 63%
“…Hg 2+ is linearly and logarithmically correlated in the range between 5 pM and 100 nM. The regression equation was Y = 0.90LogC Hg2+ − 2.40 (R 2 = 0.993), and the calculation formula for detection limit is S/N = 3 [44]. The detection limit was 0.84 pM (Figure 4B).…”
Section: Analytical Performance and Selectivity And Stabilitymentioning
confidence: 95%
“…PEC sensing employs the use of multiple chemical reaction steps to amplify the signal obtained from antigen–antibody binding, utilizing reactions such as enzyme-mediated catalysis, chemical redox cycling, nanomaterial mediated electron excitation, to name a few. As a step up from electrochemical bioanalysis, PEC possesses fast response times, good signal-to-noise ratio and high sensitivity . A competitive assay based on PEC immunosensing was developed with an extremely low LoD of 0.06 pg/mL .…”
Section: Rapid Cortisol Technologiesmentioning
confidence: 99%
“…As a step up from electrochemical bioanalysis, PEC possesses fast response times, good signal-to-noise ratio and high sensitivity. 90 A competitive assay based on PEC immunosensing was developed with an extremely low LoD of 0.06 pg/mL. 91 This type of “signal-on” immunoassay could become routine as PEC based reactions become more commonplace.…”
Section: Rapid Cortisol Technologiesmentioning
confidence: 99%