2019
DOI: 10.1016/j.wneu.2019.02.204
|View full text |Cite
|
Sign up to set email alerts
|

Tiny Pipes: 67 Cases of Flow Diversion for Aneurysms in Distal Vessels Measuring Less Than 2.0 mm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…With the expansion of indications to more distal aneurysms and the development of a newer generation of flow diverters, the application of these stent devices is likely to increase further. [1][2][3] Despite a growing body of literature on the use of the Pipeline embolization device (PED, Medtronic, Dublin, Ireland) and other flow diverters for IA treatment, the effect of multiple flow diverters in comparison to a single flow diverter on rates of aneurysm occlusion and thromboembolic complications is unclear. The use of multiple PEDs is thought to be associated with earlier occlusion but a higher rate of complications.…”
Section: Introductionmentioning
confidence: 99%
“…With the expansion of indications to more distal aneurysms and the development of a newer generation of flow diverters, the application of these stent devices is likely to increase further. [1][2][3] Despite a growing body of literature on the use of the Pipeline embolization device (PED, Medtronic, Dublin, Ireland) and other flow diverters for IA treatment, the effect of multiple flow diverters in comparison to a single flow diverter on rates of aneurysm occlusion and thromboembolic complications is unclear. The use of multiple PEDs is thought to be associated with earlier occlusion but a higher rate of complications.…”
Section: Introductionmentioning
confidence: 99%
“…There are some reports of the off-label use of a flow diverter in distal cerebral circulation. 10,[16][17][18] Figure 2. Angiographic description of the aneurysm.…”
Section: Discussionmentioning
confidence: 99%
“…Puri et al 18 and Bender et al 17 reported the efficiency and safety of using the flow diverter (Pipeline) for small vessels with diameters less than 2.5 mm and 2 mm, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…The major morbidity rate of 4.5% and mortality rate of 1.5% compare favourably to both on-label PED and small aneurysm PED series. 59…”
Section: Pipeline Embolization Devicementioning
confidence: 99%
“…60 In a series of 67 small-vessel aneurysms treated with FD, Bender et al reported five (7.5%) instances of intraprocedural stent thrombosis, all of which were successfully managed with intraprocedural abciximab dosing according to Lin et al's dosing strategy for the management of acute intraprocedural thromboembolic complications during PED treatment. 59 Intra-arterial (IA) abciximab (ReoPro) has been shown to be a safe and effective strategy for managing acute intraprocedural thromboembolic complications during PED treatment. Lin et al identified 30 cases where thromboembolic complications occurred during PED placement.…”
Section: Open Accessmentioning
confidence: 99%