2013
DOI: 10.1016/j.bone.2012.09.014
|View full text |Cite
|
Sign up to set email alerts
|

TiNOx coatings on roughened titanium and CoCr alloy accelerate early osseointegration of dental implants in minipigs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
18
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 36 publications
3
18
0
Order By: Relevance
“…Thus, we have used an animal model to evaluate bone response to Ti implants and no significant differences in terms of histological and histomorphometric parameters were observed when plasma-nitrided surfaces were compared with untreated one. In agreement with this, it has been shown that, despite modifying surface characteristics, bone formation in close contact with Ti implants is not deeply affected by nitriding treatments 9 , 15 , 24 . Bone contact, area, and volume were not affected by nitride Ti produced by powder immersion reaction assisted coating when implanted in rat femora for 8 weeks 24 .…”
Section: Discussionsupporting
confidence: 68%
See 1 more Smart Citation
“…Thus, we have used an animal model to evaluate bone response to Ti implants and no significant differences in terms of histological and histomorphometric parameters were observed when plasma-nitrided surfaces were compared with untreated one. In agreement with this, it has been shown that, despite modifying surface characteristics, bone formation in close contact with Ti implants is not deeply affected by nitriding treatments 9 , 15 , 24 . Bone contact, area, and volume were not affected by nitride Ti produced by powder immersion reaction assisted coating when implanted in rat femora for 8 weeks 24 .…”
Section: Discussionsupporting
confidence: 68%
“…Nitrided Ti surfaces produced by glow-discharge plasma treatment had no effect on bone contact and area when implanted in rabbit tibia for 1, 3, and 6 weeks 15 . On the other hand, the increased bone contact with nitrided Ti surface produced by plasma vapor observed 2 weeks post-implantation decreased after 1 and 3 months 9 . As our evaluation was carried out at 6 weeks, a period in which the process of bone formation is completed in this animal model 12 , it is possible to suggest that some effect of plama-nitrided Ti implant surfaces on bone formation, if any, could be noticed in early time-points.…”
Section: Discussionmentioning
confidence: 87%
“…Hence patient safety must be assured using biocompatibility testing. The cell lines (hOBs and the 3T3 cells) cultured for the biocompatibility assays are standard well established cell lines commonly used for the biocompatibility evaluation of materials in our laboratory 15,16,25) . Biocompatibility assays revealed relatively good cell proliferations of both types of cells cultured, hOBs as well as the 3T3 cells, on both the resin substrates.…”
Section: Discussionmentioning
confidence: 99%
“…In the literature, there are several reports on the biological reactions at TiN surfaces, mainly prepared by PVD and CVD techniques, including the responses of bone [4244], soft tissues [42, 45] blood [16, 17, 46, 47], platelets [48], human mesenchymal stem cells [49], and osteoblasts [50, 51]. Several of those studies indicate that TiN surfaces have beneficial or comparable properties in comparison with other currently and frequently used materials.…”
Section: Discussionmentioning
confidence: 99%