2018
DOI: 10.1016/j.rec.2017.04.010
|View full text |Cite
|
Sign up to set email alerts
|

Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 30 publications
1
9
0
1
Order By: Relevance
“…Ultimately, 23 studies were identified and provided data for the research analysis. 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 An additional 30 studies are considered in Appendix E1 because of their limited sample size (<250 patients). The flowsheet for selection of included studies is represented in Figure 1 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultimately, 23 studies were identified and provided data for the research analysis. 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 An additional 30 studies are considered in Appendix E1 because of their limited sample size (<250 patients). The flowsheet for selection of included studies is represented in Figure 1 .…”
Section: Resultsmentioning
confidence: 99%
“…Nine studies didn't provide information about the timing of PPI. 9,[18][19][20][21]24,25,27,29 The overall incidence of PPI reached 17% of the TAVI patients, ranging from 8.8% to 32% of the cases.…”
Section: Ppi Detailsmentioning
confidence: 99%
“…As características do procedimento também estão implicadas na ocorrência de complicações de condução peri-TAVR. Vários relatos anteriores sugeriram índices mais altos de distúrbios de ritmo com pré-dilatação de válvula nativa e válvulas autoexpansíveis, 1,[17][18][19] embora isso não tivesse sido observado em nossa amostra, como sugerido por dados mais atuais. 20,21 Procedimentos válvula-em-válvula foram associados e menos distúrbios de condução de novo (RC = 0,19) e essa diferença não foi explicada por diferenças estatisticamente significativas na condução AV ou IV pré-TAVR, de acordo com dados publicados anteriormente.…”
Section: Pinto Et Al Dependência De Pacing a Longo-prazo Após Tavrunclassified
“…Latest-generation TAVR devices have been associated with higher incidence of cardiac conduction abnormalities (CCAs). Balloon aortic valvuloplasty is routinely employed before TAVR, helping facilitate easier deployment and minimize the likelihood of coronary occlusion but increases the risk of conduction abnormalities [16, 17] and may require concurrent PPI. Cases of left bundle branch block (LBBB) and total atrioventricular (AV) block have been repeatedly reported [16, 17, 18, 19].…”
Section: Common Complications Of Tavrmentioning
confidence: 99%
“…Balloon aortic valvuloplasty is routinely employed before TAVR, helping facilitate easier deployment and minimize the likelihood of coronary occlusion but increases the risk of conduction abnormalities [16, 17] and may require concurrent PPI. Cases of left bundle branch block (LBBB) and total atrioventricular (AV) block have been repeatedly reported [16, 17, 18, 19]. Because of the proximity of the AV-node, mechanical stress and injury exerted by the deployed stent on the aortic annulus may damage the bundle of His fibers and those forming the left branch [19].…”
Section: Common Complications Of Tavrmentioning
confidence: 99%