Cardiac Pacing, Defibrillation and Resynchronization 2021
DOI: 10.1002/9781119264002.ch7
|View full text |Cite
|
Sign up to set email alerts
|

Timing Cycles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(11 citation statements)
references
References 54 publications
0
11
0
Order By: Relevance
“…These leads are passive fixation, quadripolar, coaxial design type with lengths of 78 and 88 cm. These leads use polyurethane as an outer insulator and SI-polyimide as an inner insulator [2] and are manufactured by Medtronic, Minneapolis, MN, USA. The testing was conducted using the Test Resources Q series system, which applies specific displacements or loads to various samples and measures the corresponding load or displacement.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These leads are passive fixation, quadripolar, coaxial design type with lengths of 78 and 88 cm. These leads use polyurethane as an outer insulator and SI-polyimide as an inner insulator [2] and are manufactured by Medtronic, Minneapolis, MN, USA. The testing was conducted using the Test Resources Q series system, which applies specific displacements or loads to various samples and measures the corresponding load or displacement.…”
Section: Methodsmentioning
confidence: 99%
“…These leads are serving the same purpose; however, they differ in shape, as shown in Figure 1. These leads use polyurethane (55D) as an outer insulator and SI-polyimide as an inner insulator [2]. These leads received FDA approval in 2014, and since then, there have been more than 218,000 leads implanted in the United States alone [1].…”
Section: Introductionmentioning
confidence: 99%
“…The ICD continuously tracks the heart's activity, detecting irregular rhythms such as tachycardia or 2 of 14 fibrillation. When an abnormal rhythm is identified, the device delivers an electric shock to restore a normal heartbeat [2,3]. The 6935M Sprint Quattro Secure S and 6947M Sprint Quattro Secure (Medtronic, Minneapolis, MN, USA) are high voltage leads designed to deliver a maximum of 40 joules of energy to terminate ventricular tachycardia or ventricular fibrillation.…”
Section: Introductionmentioning
confidence: 99%
“…The 6935M Sprint Quattro Secure S and 6947M Sprint Quattro Secure (Medtronic, Minneapolis, MN, USA) are high voltage leads designed to deliver a maximum of 40 joules of energy to terminate ventricular tachycardia or ventricular fibrillation. These leads play a crucial role in delivering therapeutic energy to address serious cardiac arrhythmias, providing a significant intervention in the management of these life-threatening conditions [3]. As illustrated in Figure 1, the 6935M Sprint Quattro Secure S functions as an 8.6 F (2.8 mm) active fixation true bipolar ICD lead with a single coil.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation