2016
DOI: 10.1016/j.jcms.2016.06.015
|View full text |Cite
|
Sign up to set email alerts
|

Timed-release system for periosteal expansion osteogenesis using NiTi mesh and absorbable material in the rabbit calvaria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 22 publications
1
12
0
Order By: Relevance
“…131 Frequently, NiTi SMAs are manipulated to the desired shape in vitro and then applied in vivo, e.g., as bone distractor. [132][133][134] In a recent study, a NiTi-SMA plate was heated by electromagnetic stimulation, yielding higher material stiffness, which in turn resulted in increased fixation stiffness and resulted in better bone healing in a rabbit osteotomy model. 135 Importantly, NiTi SMAs have already been used clinically, including in patients with cleft lip and palate, 136 in patients undergoing midfoot or hindfoot arthrodesis, 136 in treating adolescent idiopathic scoliosis, 137 etc.…”
Section: Piezoelectric Materialsmentioning
confidence: 99%
“…131 Frequently, NiTi SMAs are manipulated to the desired shape in vitro and then applied in vivo, e.g., as bone distractor. [132][133][134] In a recent study, a NiTi-SMA plate was heated by electromagnetic stimulation, yielding higher material stiffness, which in turn resulted in increased fixation stiffness and resulted in better bone healing in a rabbit osteotomy model. 135 Importantly, NiTi SMAs have already been used clinically, including in patients with cleft lip and palate, 136 in patients undergoing midfoot or hindfoot arthrodesis, 136 in treating adolescent idiopathic scoliosis, 137 etc.…”
Section: Piezoelectric Materialsmentioning
confidence: 99%
“…Yamauchi et al [31, 32, 38] then designed a new type of self-activated memory alloy (SMA) (Figure 1(c)); it does not need distraction screws and thus solves the complications with the minimal invasion. Nonetheless, the accuracy and controllability of the above two kinds of expansion devices were relatively poor.…”
Section: The Designs and Materials Of Distraction Devicesmentioning
confidence: 99%
“…Lethaus et al [24] put the distraction device under the calvarial bone, the result showed that the cumulative bone mass was about 66% in dynamic group and 67% in static group, and there were no significant differences between the two groups with regard to bone quality or quantity. Yamauchi et al [38] used a SMA mesh device and an absorbable thread to conduct dynamic distraction; result showed that dynamic distraction group had higher volume of newly formed bone by comparing with simple SMA group.…”
Section: Effect Of Distraction Strategies On the Formation Of New mentioning
confidence: 99%
“…Previously, a nickel-titanium (Ni-Ti) shape-memory alloy (SMA) device was used to perform PEO. 6,7,12 The innate elasticity removed the need for manual activation. Timed release of bioresorbable materials obviated any requirement for secondary surgical intervention.…”
Section: Introductionmentioning
confidence: 99%