2019
DOI: 10.1109/tim.2018.2838198
|View full text |Cite
|
Sign up to set email alerts
|

Time-Variant In-Circuit Impedance Monitoring Based on the Inductive Coupling Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…To perform time-variant in-circuit impedance measurement, the TD-TPS was developed. The TD-TPS was first for time-variant in-circuit impedance monitoring of switching circuits [14]. It was later employed for voltage-dependent capacitances extraction of power semiconductor devices [8] and stator insulation faults detection of induction motors [17].…”
Section: Time-domain Two-probe Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…To perform time-variant in-circuit impedance measurement, the TD-TPS was developed. The TD-TPS was first for time-variant in-circuit impedance monitoring of switching circuits [14]. It was later employed for voltage-dependent capacitances extraction of power semiconductor devices [8] and stator insulation faults detection of induction motors [17].…”
Section: Time-domain Two-probe Setupmentioning
confidence: 99%
“…To measure the in-circuit impedance of one SUT, the measurement setups of the inductive coupling approach can be mainly divided into the frequency-domain two-probe setup (FD-TPS) [9]- [13], the time-domain two-probe setup (TD-TPS) [14]- [17] and the frequency-domain single-probe setup (FD-SPS) [18]- [20]. Besides, the multi-probe setup (MPS) was also designed but it is for simultaneous measurement of in-circuit impedances of multiple SUTs in multi-branches powered by the same power source [21], [22].…”
Section: Introductionmentioning
confidence: 99%
“…Hence the DFT can be used to monitor Zloop in real time [7]. Once V1 and V2 are obtained, Zloop can be obtained through the equation stated above.…”
Section: Figure 3 -Moving Window Discrete Fourier Transform Algorithmmentioning
confidence: 99%
“…For this paper, a non-intrusive impedance extraction online method that is based on the inductive coupling approach [4][5][6][7], is used for detecting insulation fault within the stator winding of the induction motor. A known signal generated is input into the induction motor and monitored simultaneously.…”
Section: Introductionmentioning
confidence: 99%
“…The voltage of the test signal at the input terminal and voltage of the feedback signal at the output terminal of the IIP is then being processed by channel 0 (CH0) and channel 1 (CH1) of the signal acquisition card (SAC) within the SGAS, respectively. The impedance contributed by the source voltage and electrical wirings excluding the sections that are being clamped by the probes of the measurement setup is denoted as ZS and ZW respectively, as shown in Figure8[25]. The equivalent impedance measured by the two probes can be represented by ZX, where š’ š‘æ = š’ š‘ŗ + š’ š‘¾ + š’ š‘«š‘¼š‘»(7)…”
mentioning