2018
DOI: 10.1007/s00348-018-2583-3
|View full text |Cite
|
Sign up to set email alerts
|

Time-resolved PIV measurements in a low-aspect ratio facility of randomly packed spheres and flow analysis using modal decomposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 36 publications
(10 citation statements)
references
References 69 publications
0
10
0
Order By: Relevance
“…A more recent study was aimed at simulating the flow in a random pebble bed. 37 This random pebble-bed geometry was obtained from an experiment conducted by Nguyen et al 38 The experiment measured detailed velocity distributions using particle image velocimetry (PIV) and matched index of refraction within a pebble bed. A DNS of the flow field was then conducted for a short section of the bed comprising 147 pebbles, corresponding to the test section and additional layers of pebbles.…”
Section: Iiia3 Pebble Bedsmentioning
confidence: 99%
“…A more recent study was aimed at simulating the flow in a random pebble bed. 37 This random pebble-bed geometry was obtained from an experiment conducted by Nguyen et al 38 The experiment measured detailed velocity distributions using particle image velocimetry (PIV) and matched index of refraction within a pebble bed. A DNS of the flow field was then conducted for a short section of the bed comprising 147 pebbles, corresponding to the test section and additional layers of pebbles.…”
Section: Iiia3 Pebble Bedsmentioning
confidence: 99%
“…For each flow measurement of the tested materials, the camera operated in a single-frame mode and captured a sequence of 8341 images of 1280 × 1280 pixels at a frequency of 500 Hz. The collection of PIV experimental images was processed using in-house codes ( Eckstein and Vlachos, 2009 , Nguyen et al, 2017 , Nguyen and Hassan, 2017 , Nguyen et al, 2018a , Nguyen et al, 2018b , Nguyen et al, 2019a , Nguyen et al, 2019b , Nguyen et al, 2019c , Nguyen et al, 2020 ). The estimated overall uncertainty of the PIV processing code was approximately 0.1 pixels, yielding less than 1% of the mean centerline velocity of the upstream region.…”
Section: Materials Experimental Facility and Measurement Techniquesmentioning
confidence: 99%
“…A more recent study was aimed at simulating the flow in a random pebble bed [7]. This random pebble bed geometry was obtained from an experiment conducted by Nguyen et al [8]. However, only a small section of the whole domain from the experiment was studied.…”
Section: Verification and Validationmentioning
confidence: 99%