Time-resolved multi-mass ion imaging: Femtosecond UV-VUV pump-probe spectroscopy with the PImMS camera

Abstract: The Pixel-Imaging Mass Spectrometry (PImMS) camera allows for 3D charged particle imaging measurements, in which the particle time-of-flight is recorded along with (x, y) position. Coupling the PImMS camera to an ultrafast pump-probe velocity-map imaging spectroscopy apparatus therefore provides a route to time-resolved multi-mass ion imaging, with both high count rates and large dynamic range, thus allowing for rapid measurements of complex photofragmentation dynamics. Furthermore, the use of vacuum ultraviol… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 57 publications
0
23
0
Order By: Relevance
“…The TRPES experiments utilized a standard pump-probe spectroscopy scheme [68]. A seeded supersonic beam injected CH 2 I 2 molecules through a pulsed valve into the interaction region of an electron velocity map imaging (VMI) spectrometer [69], where they interacted with the fs UV-pump and VUV-probe pulses.…”
Section: A Trpes Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…The TRPES experiments utilized a standard pump-probe spectroscopy scheme [68]. A seeded supersonic beam injected CH 2 I 2 molecules through a pulsed valve into the interaction region of an electron velocity map imaging (VMI) spectrometer [69], where they interacted with the fs UV-pump and VUV-probe pulses.…”
Section: A Trpes Experimentsmentioning
confidence: 99%
“…The gas-phase UED and TRPES experimental apparatuses have been described in detail previously [52,68]. Here, we expand on the discussion in the main text to describe experimental conditions for the two measurements in some more detail.…”
Section: Trpes and Ued Experimental Detailsmentioning
confidence: 99%
See 1 more Smart Citation
“…The femtosecond VUV pulse generation scheme employed in these experiments was described in detail previously. 25 In short, the laser system (Coherent Legend Elite Duo) employed throughout these experiments delivered 7.5 mJ pulses at 1 kHz, with a central frequency of 800 nm. A 3.25 mJ component of the total laser output was split to generate the pump and probe arms.…”
Section: A Experimentalmentioning
confidence: 99%
“…The experimental set-up used for the VUV-UV pumpprobe photoelectron velocity-map imaging (VMI) measurements at 133 nm reported herein was almost identical to that previously reported for work using 160 nm radiation [25], and the reader is referred to that work for further details of the experimental apparatus beyond the outline sketched here. A similar VUV-UV pump-probe VMI experimental configuration has also been previously reported by Suzuki (see ref.…”
Section: A Vuv-uv Photoelectron Imagingmentioning
confidence: 92%