Time-resolved measurement of plasma parameters by means of triple probe

Abstract: Triple Langmuir probe (TLP) diagnostic system with its necessary driving circuit is developed and successfully applies for time-resolved measurement of plasma parameters in the negative glow region of pulsating-dc discharge. This technique allows the instantaneous measurement of electron temperature [T_], electron number density [n_] as well as plasma fluctuations without any voltage or frequency sweep. In TLP configuration two probes are differentially biased and serve as a floating symmetric double probe whe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(25 citation statements)
references
References 23 publications
0
22
0
Order By: Relevance
“…The Langmuir Triple probe is a disseminated technique for the diagnosis of plasma, which can provide the electronic temperature, i.e., the average energy of the electrons [ 56 , 57 ]. Then, it is possible to correlate the average energy of the electrons with the energy of the chemical bond, estimating the functional groups generated superficially during the plasma treatments [ 58 , 59 , 60 , 61 ].…”
Section: Methodsmentioning
confidence: 99%
“…The Langmuir Triple probe is a disseminated technique for the diagnosis of plasma, which can provide the electronic temperature, i.e., the average energy of the electrons [ 56 , 57 ]. Then, it is possible to correlate the average energy of the electrons with the energy of the chemical bond, estimating the functional groups generated superficially during the plasma treatments [ 58 , 59 , 60 , 61 ].…”
Section: Methodsmentioning
confidence: 99%
“…The plasma density and temperature were measured with a triple Langmuir probe [34,35]. It consisted of three identical probe tips made of a tungsten wire with a diameter 0.6 mm and length 4.5 mm inserted axially within the plasma jet at a distance of 4 cm.…”
Section: Methodsmentioning
confidence: 99%
“…The voltage V dif between the floating probe 2 # and the biased probe 1 # was measured with a differential voltage amplifier. The electron temperature is deduced from the following equation [35]:…”
Section: Methodsmentioning
confidence: 99%
“…The probe circuit used here for GLAST-III does not contain any compensation for stray capacitance of the cables due to its negligible effect on cut-off frequency for relativity high electron density and temperature of ECRH-assisted microwave plasma. However, the effect of stray capacitance on cut-off frequency can be reduced significantly in low density and temperature plasmas by using appropriate guarding circuit [13][14][15]. Moreover, probe head is shielded by cylindrical aluminium casing that provides protection against electromagnetic noise and also serves as reference electrode for probe measurements during microwave discharge.…”
Section: Probe Design and Constructionmentioning
confidence: 99%
“…The toroidal electrical field requirement for breakdown can & A. Qayyum abdul.qaui@yahoo.com be reduced significantly by adopting various pre-ionization schemes during startup phase [15][16][17]. ECRH-assisted current startup is a scheme for generating toroidal plasma currents in tokomaks [18][19][20].…”
Section: Introductionmentioning
confidence: 99%