2014
DOI: 10.2116/analsci.30.219
|View full text |Cite
|
Sign up to set email alerts
|

Time-resolved ICP-MS Measurement: a New Method for Elemental and Multiparametric Analysis of Single Cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(20 citation statements)
references
References 47 publications
(93 reference statements)
0
20
0
Order By: Relevance
“…The quantification of iron load internalized into BM-MNC by NIRF, MRI, and ICP-MS (Table 2) showed signal detection according to the signal detection limitation of each technique as a function of their sensibility, spatial, and temporal resolutions [17,46]. Some studies reported an internalization of 0.69 ± 0.08 [47]; 1.33 ± 0.2 [48]; 2.01 ± 0.10 pg [49] of nanoparticles per HSC.…”
Section: Discussionmentioning
confidence: 99%
“…The quantification of iron load internalized into BM-MNC by NIRF, MRI, and ICP-MS (Table 2) showed signal detection according to the signal detection limitation of each technique as a function of their sensibility, spatial, and temporal resolutions [17,46]. Some studies reported an internalization of 0.69 ± 0.08 [47]; 1.33 ± 0.2 [48]; 2.01 ± 0.10 pg [49] of nanoparticles per HSC.…”
Section: Discussionmentioning
confidence: 99%
“…This limitation can be overcome in time-resolved ICP-MS for single-cell analysis (Bendall et al 2012). Here, a cell suspension is passed to a plasma torch via a nebulizer or microdroplet dispenser followed by the generation of the ion cloud, which can be analyzed as an individual signal with a high time resolution (Miyashita et al 2014). A schematic representation of time-resolved ICP-MS for elemental analysis of single-cell is given in Fig.…”
Section: Inductively Coupled Plasma Mass Spectrometry (Icp-ms)mentioning
confidence: 99%
“…The lower region of the plot (P3) indicates the presence of human CD4 + T cells in human CD4 + T gate. They (Miyashita et al 2014). (ii) Human CD4 + T cells (purity 97.2%) were labeled with Gd-DTPA-BMA, washed extensively, and administered intraperitoneally (2 Â 10 6 ) to BALB/c immunodeficient mice together with 3 Â 10 6 autologous PBMC.…”
Section: Inductively Coupled Plasma Mass Spectrometry (Icp-ms)mentioning
confidence: 99%
“…In recent years, time-resolved ICP-MS, known as single-cell ICP-MS (SC-ICP-MS), has attracted a great deal of interest for multielemental analysis of single cells as an alternative of classical bulk analysis of large amounts of cells with a lysis, extraction, or digestion (Miyashita et al 2014a(Miyashita et al , 2017Mueller et al 2014;Wang et al 2017a). This technique is able to detect and quantify metallic elements in individual cells with high sensitivity, with the advantage of obtaining information about cellto-cell variations instead of the average information from large cell populations obtained by conventional bulk measurements.…”
Section: Time Resolved Icp-ms Analysismentioning
confidence: 99%