2020
DOI: 10.1016/j.bios.2020.112284
|View full text |Cite
|
Sign up to set email alerts
|

Time-resolved fluorescence resonance energy transfer-based lateral flow immunoassay using a raspberry-type europium particle and a single membrane for the detection of cardiac troponin I

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 60 publications
(30 citation statements)
references
References 26 publications
0
30
0
Order By: Relevance
“…The electrochemical properties of the sensor was further investigated by EIS. In EIS, semicircular and straight regions indicate electron transfer-limited processes and mass transfer control processes (Demirbakan and Kemal Sezgintürk, 2020;Lee et al, 2020), respectively. Considering the variation of the electron transfer resistance (R ct ), the EIS method can provide important information to demonstrate the interaction between the aptamer and the target protein.…”
Section: Resultsmentioning
confidence: 99%
“…The electrochemical properties of the sensor was further investigated by EIS. In EIS, semicircular and straight regions indicate electron transfer-limited processes and mass transfer control processes (Demirbakan and Kemal Sezgintürk, 2020;Lee et al, 2020), respectively. Considering the variation of the electron transfer resistance (R ct ), the EIS method can provide important information to demonstrate the interaction between the aptamer and the target protein.…”
Section: Resultsmentioning
confidence: 99%
“…More importantly, LOD reached a value as low as 17 pg mL −1 . Compared with other reports related to cTnI determination (Table 1), 13,[37][38][39][40][41][42][43][44][45] the prepared lanthanide-doped NPs-based LFA has the merits of relatively low LOD and wide linear range. As for colorimetry, it is hard to distinguish the intermediate color with the naked eye.…”
Section: Analytical Performance Of Lfa Platformmentioning
confidence: 86%
“…LFA can use different materials to label antibody such as latex beads [11], carbon nanoparticles [12], colloidal silver [13], dye-loaded liposomes [14], gold nanoparticles (AuNPs) [7], europium chelate-loaded silica nanoparticles [15], quantum dots [16] and upconverting phosphors [17]. Each label is able to create different characteristics in the diagnostic platform, but the main purpose in using different labels is to try to make a more sensitive assay.…”
Section: Design and Principle Of Lateral Flow Assaysmentioning
confidence: 99%