2022 International Symposium on Electromagnetic Compatibility – EMC Europe 2022
DOI: 10.1109/emceurope51680.2022.9901170
|View full text |Cite
|
Sign up to set email alerts
|

Time-domain Multitone Impedance Measurement System for Space Applications

Abstract: This paper presents a time-domain methodology to measure the devices' live impedance at the frequency range between 30 Hz and 100 kHz. This measurement is a requirement for some space applications to ensure the stability between DC/DC converters and the onboard power. The methodology is based on a multitone excitation combined with current and voltage measurements performed with an oscilloscope. The experiments show that the measurement system obtains accurate results and offers new capabilities to deal with t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 14 publications
0
0
0
Order By: Relevance
“…Likewise, reducing dynamic range compression effects by lowering the multitone signal crest factor is desirable. This is possible by appropriately selecting the relative phases of the individual tones, according to the criterion in [23].…”
Section: B Reference Signalsmentioning
confidence: 99%
“…Likewise, reducing dynamic range compression effects by lowering the multitone signal crest factor is desirable. This is possible by appropriately selecting the relative phases of the individual tones, according to the criterion in [23].…”
Section: B Reference Signalsmentioning
confidence: 99%
“…The multitone has the advantage of using a low crest factor when the phases of the tones are properly selected. If an AWG generates full periods of the signal, no leakage is produced, and a very high dynamic range can be achieved [5]. A single instrument for the complete verification.…”
Section: Proposed Improvements a Improvements Descriptionmentioning
confidence: 99%
“…2) CE verification: Regarding the CE verification, we employ the AWG available at an R&S RTO6 oscilloscope to generate the multitone excitation. As detailed in past studies, reducing the crest factor of the excitation signal is crucial to obtain a high dynamic range [5], [12]. Hence, the Schroeder [13] approach has been applied to compute the tone phases to minimize the crest factor.…”
Section: B Validation Measurements Of the Proposed Improvementsmentioning
confidence: 99%