2010
DOI: 10.1016/j.biologicals.2010.02.012
|View full text |Cite
|
Sign up to set email alerts
|

Thromboplastin standards

Abstract: The Prothrombin Time (PT) test is used for monitoring of treatment with Vitamin K-antagonists (VKA). The result of the PT test should be expressed as the International Normalized Ratio (INR). Calculation of INR is based on the availability of International Standards (IS) for thromboplastin and a calibration model. Calibration of a new PT test system is performed with the appropriate IS and fresh plasma samples of healthy (normal) volunteers and patients treated with VKA. The calibration model is based on the a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
15
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 47 publications
0
15
0
Order By: Relevance
“…The observed differences may be due to instability of the plasma samples at room temperature [11]. International Standards for thromboplastin have an established value for the International Sensitivity Index (ISI) [1][2][3]. The ISI values for RBT/05 and rTF/09 were established in 2005 and 2009, respectively.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The observed differences may be due to instability of the plasma samples at room temperature [11]. International Standards for thromboplastin have an established value for the International Sensitivity Index (ISI) [1][2][3]. The ISI values for RBT/05 and rTF/09 were established in 2005 and 2009, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…The difference plot of the natural logarithms of prothrombin times indicated a significant correlation (P = 0.013). parameter used for calibration of secondary standards [1,8]. As no material is absolutely stable, it has to be verified whether the real value after some time of storage still corresponds to the assigned (i.e.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, heparin has antiplatelet effects that may last longer than the measurable effect of heparin and APTT [13]. Meanwhile, the evidence to maintain a therapeutic INR during the procedure is based on more consistent data of cohorts and randomized trials [14,15]. Performing surgery under anticoagulation can facilitate the detection of small bleedings during the procedure [16].…”
mentioning
confidence: 99%
“…First, the ISI difference might be due to different blood collection tubes or other differences in pre-analytical conditions between the original calibration studies for OBT/79 and RBT/05 [3][4][5]. Second, a bias might have been introduced by multiple consecutive calibrations of the International Standards with asymmetric exclusion of samples [6,7]. Third, a physical or chemical change of at least one of these reference materials during long-term storage at low temperature cannot be excluded but is not very likely [8].…”
mentioning