2008
DOI: 10.1510/icvts.2007.169326
|View full text |Cite
|
Sign up to set email alerts
|

Thrombocytopenia after aortic valve replacement with the Freedom Solo stentless bioprosthesis

Abstract: Stentless bioprostheses have been considered to achieve superior hemodynamics over stented bioprostheses for aortic valve replacement with improved long-term performance. We observed severe thrombocytopenia in patients who received the Sorin Freedom Solo aortic stentless pericardial bioprosthesis within the first days after implantation. Absolute and relative platelet counts within 2 weeks after implantation of either a stentless (Sorin Freedom Solo) or a stented (Sorin Mitroflow) bovine pericardial bioprosthe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
48
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(53 citation statements)
references
References 2 publications
5
48
0
Order By: Relevance
“…A repeatedly reported complication after implantation of the SFS is thrombocytopenia. 12,13) In our matched study 17) Considering the geometric dimensions of the LDP and the SFS ( Table 1), with a higher orifice diameter of the SFS in the same labeled valve size (3 mm), one would expect a distinct advantage of the stentless valve in our study results. However, results of our matched analysis showed no significant difference in EOA or EOAI.…”
Section: Discussionmentioning
confidence: 78%
“…A repeatedly reported complication after implantation of the SFS is thrombocytopenia. 12,13) In our matched study 17) Considering the geometric dimensions of the LDP and the SFS ( Table 1), with a higher orifice diameter of the SFS in the same labeled valve size (3 mm), one would expect a distinct advantage of the stentless valve in our study results. However, results of our matched analysis showed no significant difference in EOA or EOAI.…”
Section: Discussionmentioning
confidence: 78%
“…The toxic effect cannot be eliminated by rinsing the valve in similar manner such as glutaraldehyde-fixed bioprostheses. (16) All these researches were not associated with thromboembolic or hemorrhagic complications. However, a research done by Beholz S. and associates which published in 2010 revealed none of the patients reported to have severe thrombocytopenia as a compli-cation.…”
Section: Discussionmentioning
confidence: 94%
“…Mean echocardiographic data collected in short and mid-term by different studies show a low number of paravalvular leakage and aortic regurgitation. (7,16,17) However, early complications did occur in 2 patients. One patient had left hand ischaemia and low cardiac output syndrome 20 days after the operation and the other one had hemorrhage from the sternal wire puncture site a day after valve replacement.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, long-term survival has not been shown to be significantly different in randomised studies (6,7) . Sorin Freedom Solo and Sorin Pericarbon Freedom are the latest generation of stentless aortic tissue valves, which have structural flexibility, an easy single-suture implantation technique and excellent haemodynamics (8,9) . However, postoperative thrombocytopaenia (TCP) is a potentially serious problem following implantation, and recent reports have suggested a strong relationship (10)(11)(12)(13)(14)(15)(16)(17)(18) .…”
Section: Introductionmentioning
confidence: 99%