Threshold value of DC array current and DC string voltage for fault detection in grid-connected photovoltaic system

Abstract: The failure detection in a grid-connected photovoltaic (PV) system has become an important aspect of solving the issue of the reduced energy output in the PV system. One of the methods in detecting failure is by using the threshold-based method to compute the ratio of actual and predicted DC array current and DC string voltage value. This value will be applied in the failure detection algorithm by using power loss analysis and may reduce the time, cost and labour needed to measure the quality of the energy out… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 12 publications
(20 reference statements)
0
3
0
Order By: Relevance
“…The pre-setting current and voltage, given the number of connected panels in series and parallel PV configurations, implement an automated fault-diagnostics technique. This technique offers reasonable simplification and effectiveness in diagnosing the faults for grid-connected PV systems [67]. Electrical signatures such as current and voltage are employed as fault indicators for partial shading and inverter disconnection.…”
Section: Working Conditions Loss (%)mentioning
confidence: 99%
“…The pre-setting current and voltage, given the number of connected panels in series and parallel PV configurations, implement an automated fault-diagnostics technique. This technique offers reasonable simplification and effectiveness in diagnosing the faults for grid-connected PV systems [67]. Electrical signatures such as current and voltage are employed as fault indicators for partial shading and inverter disconnection.…”
Section: Working Conditions Loss (%)mentioning
confidence: 99%
“…Another study by Muhammad et al [15], perform the ratio of voltage and current for fault detection algorithm. This technique calculates the discrepancy in measured and modelled PV system outputs is used to detect faults.…”
Section: Introductionmentioning
confidence: 99%
“…There are several factors that contribute to the performance of a solar photovoltaic (PV) such as level of solar irradiance, photovoltaic material, panel orientation, temperature as well as soiling. In addition, shading factor is also affecting the solar production [3,4]. Therefore, in order to maximize the solar energy production, a tracking mechanism known as maximum power point tracking (MPPT) is vital in orienting the solar panel accurately towards the solar radiation as the direction continuously varies over a day.…”
Section: Introductionmentioning