2020 IEEE Energy Conversion Congress and Exposition (ECCE) 2020
DOI: 10.1109/ecce44975.2020.9235445
|View full text |Cite
|
Sign up to set email alerts
|

Three-Phase Unified Power Quality Conditioner based on H-bridge and High-Frequency Link

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…High-frequency transformers can be used to implement the isolated bidirectional converters, which enables for equipment that is smaller, lighter, and less expensive. Since the non-linearity and losses of the low-frequency transformers are eliminated from the system, it is also anticipated that the UPQC will perform better in compensating the power quality issues and have a higher efficiency as its series and shunt converters connect to the power grid without transformers [70].When the circulating power between the series and shunt converters is low and there is little power loss in the isolated bidirectional dc-dc converters, the efficiency enhancement is most apparent [71].…”
Section: Transformerless Series Active Power Filtersmentioning
confidence: 99%
See 1 more Smart Citation
“…High-frequency transformers can be used to implement the isolated bidirectional converters, which enables for equipment that is smaller, lighter, and less expensive. Since the non-linearity and losses of the low-frequency transformers are eliminated from the system, it is also anticipated that the UPQC will perform better in compensating the power quality issues and have a higher efficiency as its series and shunt converters connect to the power grid without transformers [70].When the circulating power between the series and shunt converters is low and there is little power loss in the isolated bidirectional dc-dc converters, the efficiency enhancement is most apparent [71].…”
Section: Transformerless Series Active Power Filtersmentioning
confidence: 99%
“…By balancing the three phase harmonic reference current, the multilayer structure can reduce device ratings. The half bridge converter topology is sometimes applied in studies involving multilevel technology, as in [175]. Additionally, experimental RPC MMC findings are shown in [176].…”
Section: Modular Multilevel Converters For Lowering Switching Frequen...mentioning
confidence: 99%
“…The isolated bidirectional converters can be implemented using high-frequency transformers, which allows for reducing the size, weight, and cost of equipment. As the series and shunt converters of the UPQC connect to the power grid without transformers it is also expected a better performance of the UPQC in compensating the power quality problems and a higher efficiency since the non-linearity and losses of the low-frequency transformers are removed from the system [242]. The increase in the efficiency is most noticeable when the circulating power between the series and shunt converters is small, leading to low power loss in the isolated bidirectional dc-dc converters [243].…”
Section: Transformerless Series Active Power Filtersmentioning
confidence: 99%