TENCON 2006 - 2006 IEEE Region 10 Conference 2006
DOI: 10.1109/tencon.2006.344163
|View full text |Cite
|
Sign up to set email alerts
|

Three-Phase Two-Leg Inverter for Stand-Alone and Grid-Connected Renewable Energy Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 11 publications
0
6
0
Order By: Relevance
“…However, the system proposed in [43] reduces the insulation capacity of the back-to-back converter against the propagation of electrical disturbances between the DFIG rotor circuit and the grid. In [44], it is proposed the use the 2L2B topology, as GSC, connected to a DC/DC full-bridge converter by the DC link, to ensure greater stability and electrical insulation between the AC and DC sides. However, the structure presented in [44] would make the back-to-back converter more expensive and with more complex control due to the use of more magnetic semiconductors and capacitors.…”
Section: Rsc Gscmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the system proposed in [43] reduces the insulation capacity of the back-to-back converter against the propagation of electrical disturbances between the DFIG rotor circuit and the grid. In [44], it is proposed the use the 2L2B topology, as GSC, connected to a DC/DC full-bridge converter by the DC link, to ensure greater stability and electrical insulation between the AC and DC sides. However, the structure presented in [44] would make the back-to-back converter more expensive and with more complex control due to the use of more magnetic semiconductors and capacitors.…”
Section: Rsc Gscmentioning
confidence: 99%
“…In [44], it is proposed the use the 2L2B topology, as GSC, connected to a DC/DC full-bridge converter by the DC link, to ensure greater stability and electrical insulation between the AC and DC sides. However, the structure presented in [44] would make the back-to-back converter more expensive and with more complex control due to the use of more magnetic semiconductors and capacitors. In [45] the 2L2B topology is employed as GSC, while the conventional 2L3B topology is used as RSC, such as proposed in this paper.…”
Section: Rsc Gscmentioning
confidence: 99%
See 1 more Smart Citation
“…Fig. 3(b) shows a single-phase three-wire (1P3W) half-bridge VSI topology that generates stable sinusoidal voltages or achieves PQ compensation [50]. In [51], a new active filtering technique was proposed as the interface between single-phase VSI and the utility grid.…”
Section: A Power Circuit Structurementioning
confidence: 99%
“…Renewable energy sources (such as wind turbines, photovoltaic arrays, biomass, and fuel cells) are increasingly preferred in distributed generation systems (DGSs) in order to reduce global warming gas emissions [1]. In recent years, since the grid connection of rural villages or remote islands has higher costs than the stand-alone operations, stand-alone DGSs applications for those cases are gaining more attention [1][2][3][4][5][6][7]. The inverter of the DGS can be considered as an uninterruptible power supply (UPS) for its local loads in stand-alone applications [1].…”
Section: Introductionmentioning
confidence: 99%