1995
DOI: 10.2172/572430
|View full text |Cite
|
Sign up to set email alerts
|

Three dimensional zone of capture analysis for the A/M-area

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
13
0

Year Published

1996
1996
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 2 publications
2
13
0
Order By: Relevance
“…(Looney and Phifer, 1994) The influence of RWM-16 in providing plume containment and control within the Southern Sector has been examined in the latest zone of capture analysis. (Jackson and Aleman, 1995) This analysis indicated that RWM-16 provides capture of only a portion of the groundwater plume that is currently located within the Southern Sector. The analysis revealed that in order to accomplish complete plume control and capture within the Southern Sector additional wells and extraction volume are required.…”
Section: Southern Sectormentioning
confidence: 96%
See 3 more Smart Citations
“…(Looney and Phifer, 1994) The influence of RWM-16 in providing plume containment and control within the Southern Sector has been examined in the latest zone of capture analysis. (Jackson and Aleman, 1995) This analysis indicated that RWM-16 provides capture of only a portion of the groundwater plume that is currently located within the Southern Sector. The analysis revealed that in order to accomplish complete plume control and capture within the Southern Sector additional wells and extraction volume are required.…”
Section: Southern Sectormentioning
confidence: 96%
“…The system provides groundwater remediation via pump and treat technology for the Central A/M Area. (Jackson and Aleman, 1995) In addition to the dissolved plume present in the Central A/M Area, NAPL is present in both the unsaturated and saturated zones. (Looney et al, 1992) To address and remediate the NAPL in the unsaturated zone a series of soil vapor extraction units have been installed in the source zone regions along the process sewer line and beneath the M-Area Basin.…”
Section: Central Aim Areamentioning
confidence: 99%
See 2 more Smart Citations
“…The central A/M Area is defined based upon zone of capture mcxleling for this system and its effectiveness has been evaluated through extensive groundwater modeling activities. (Papadopulos & Associates 1987, Haselow et.al 1991 Previous modeling activities evaluated the effectiveness of the pump& treat system (Jackson and Aleman, 1995) with regards to remediation goals in the Tertiary sediments. The previous investigation identified the 5, 15, and 30 year zone of capture in the "Middle Sand" aquifer zone, the Lost Lake aquifer zone, and in the M-Area aquifer zone.…”
Section: Pump and Treat Systemmentioning
confidence: 99%