2012
DOI: 10.1016/j.ejrad.2011.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional volume rendering digital subtraction angiography in comparison with two-dimensional digital subtraction angiography and rotational angiography for detecting aneurysms and their morphological properties in patients with subarachnoid hemorrhage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0
1

Year Published

2012
2012
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 14 publications
0
20
0
1
Order By: Relevance
“…Our observation suggests that 3D angiography is more sensitive to, and thus more suitable for the detection of, these small aneu rysms than conventional angiography. 20 Considering the literature and our own observations, it is also probable that the incidence of LSA aneurysms is underestimated.…”
Section: Discussionmentioning
confidence: 99%
“…Our observation suggests that 3D angiography is more sensitive to, and thus more suitable for the detection of, these small aneu rysms than conventional angiography. 20 Considering the literature and our own observations, it is also probable that the incidence of LSA aneurysms is underestimated.…”
Section: Discussionmentioning
confidence: 99%
“…[135][136][137][138] In addition, the resolution provided by DSA is greater for the smallest of vessels, such as perforators. [139][140][141][142][143][144] Although DSA remains the gold standard, it should be recognized that catheter arteriography does have risks, albeit small. Possible complications include contrast-related events, cerebral infarction, aneurysmal rupture, arterial injury, and others.…”
Section: -134mentioning
confidence: 99%
“…Volume rendering (VR) is a technique commonly used for the reconstruction of 3D DSA images [3][4][5][6][7][8][9][10], and the rendering parameters greatly affect the characteristics of the 3D image [11,12]. To our knowledge, no study has identified the optimal rendering parameters for 3D DSA images.…”
Section: Introductionmentioning
confidence: 95%
“…2 Rotational 2D DSA images in which the mean diameter was calculated as a true value by syngo AX vessel analysis software at thresholds of 4500 (a), 2500 (b), and 500 (c) Fig. 3 In the region of the 620×620 area at the center of the rotational 2D DSA image (a), the contrast-enhanced area was extracted (b) [5][6][7][8][9][10]. These injection parameters are considered not optimal and seem to be excessive in order to ensure examination success.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation