2022
DOI: 10.1016/j.prosdent.2020.09.057
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
31
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(32 citation statements)
references
References 12 publications
1
31
0
Order By: Relevance
“…3 PEEK is advantageous in terms of light reflection, which is a shortcoming of Ti 3,5,6 ; yet it may undergo changes when exposed to thermal processes. [7][8][9] In addition, possible alterations of the base due to repeated use or sterilization might affect a scan's accuracy due to displacement of the SB. 5,10 Regardless of the material it is fabricated from, a SB needs to be tightened onto the implant before data acquisition.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…3 PEEK is advantageous in terms of light reflection, which is a shortcoming of Ti 3,5,6 ; yet it may undergo changes when exposed to thermal processes. [7][8][9] In addition, possible alterations of the base due to repeated use or sterilization might affect a scan's accuracy due to displacement of the SB. 5,10 Regardless of the material it is fabricated from, a SB needs to be tightened onto the implant before data acquisition.…”
Section: Introductionmentioning
confidence: 99%
“…Effect of different torque values on buccolingual displacement has also been reported. 15 Considering that torque values are not commonly provided by the manufacturers 7 and hand tightening is inconsistent, 16,17 clinicians may benefit from studies on potential linear displacements of SBs when tightened under different torque values. The authors are aware of only two studies that investigated the effect of SB displacement depending on torque value.…”
Section: Introductionmentioning
confidence: 99%
“…When comparing the differences according to the scan body materials in this study, the titanium scan body showed a better trueness value than the PEEK scan body. To avoid possible interferences from scan body shape 20 , 21 , PEEK and titanium scan bodies from the same manufacturer were selected in this study. In this way, we tried to evaluate the independent effect of scan body materials on scan data accuracy.…”
Section: Discussionmentioning
confidence: 99%
“…Another study reported worse accuracy in inclined implants 14 , and others have reported no significant difference 6 , 7 , 15 18 . Furthermore, the scan body design can affect the accuracy of digital implant impressions 10 , 19 21 . Various types of scan bodies developed by different manufacturers are being used, and recently, multi-purpose scan bodies made of biocompatible titanium have been introduced as a healing abutment 4 .…”
Section: Introductionmentioning
confidence: 99%
“…Limited published data is available to determine the optimal implant scan body geometry and material for maximizing the scanning accuracy of intraoral digital scans involving single or multiple implants. [58][59][60][61][62][63][64][65] Different scan body designs have been tested aiming to simplify the digitizing procedures and to increase intraoral scanning accuracy. 48,64,65 However, the restricted clinical data does not support a systematic recommendation for selecting an implant scan body design.…”
Section: Implant Scan Bodiesmentioning
confidence: 99%